MAINTENANCE
Fuel Tank Filter
To clean, remove fuel cap and filter.
Clean filter with gasoline.
Wipe the filter with a clean rag.
Install filter.
Install fuel cap.
Fuel Filter
To clean, remove screws, remove outer casing, and drain fuel.
Lift and hold onto the clamp, then remove hose from tank.
Take out fuel filter.
Clean filter with gasoline.
Wipe the filter with a clean rag and return filter to tank.
Install hose and clamp.
Open fuel valve. Inspect for leakage.
Install outer casing and tighten screws
.
Storage and Transportation
of the Generator:
When transporting the generator, turn the 3 in 1 Start Switch (ON / OFF and Choke) OFF. Keep the generator level to
prevent fuel spillage. Fuel vapor or spilled fuel may ignite.
Remove any debris that has collected on the generator and around the muffler and control panel. Use a brush or vacuum
to remove loose dirt.
Inspect air cooling slots. Remove any debris if obstructed.
For short-term storage, start the generator once every 7days.
For semi-long term storage, add fuel stabilizer to prevent stale fuel from causing acid and gum deposits in the fuel system
and carburetor.
For long-term storage, drain the fuel.
Store indoors to prevent freezing and use aprotective cover to protect from dust.
The generator must be Shipped, Run, and Stored in the upright position as seen
in this image.