Hold the clamp ring (3) vertically below the screw nut/body items and screw the body (6)
into the threads on the clamp ring (3). Tighten it only enough to stay attached. Note that the
screw nut (5) remains loose on the body (6).
7.
Remove the white backing paper from one of the RJ-45 gaskets (8) and press the glued side
onto the body (6) being very careful to align the gasket (8) with the RJ-45 connector shape
on the body (6).
8.
Remove the backing paper from the second RJ-45 gasket (8) and press it over the first one,
being sure to maintain alignment.
9.
Tighten the threads between body (6) and clamp Ring (3) by hand. DO NOT tighten between
clamp ring (3) and sealing nut (1). Do not over tighten. Do not tighten with tools.
The quick-disconnect assembly should now look like this when held horizontally, with the
sealing nut (1) at the left end, and the screw nut (5) over the body (6) on the right.
Figure 3 Quick-disconnect assembly
10. Carefully thread the cleanly-cut end of the Ethernet cable through the sealing nut (1) end of
the quick-disconnect assembly, and push through approximately 30 cm (1 foot) of cable.
NOTE:
cables.
1 1. Prepare the cable and attach it to the RJ-45 Plug (7) according to the directions included with
your crimping tool.
12. Before continuing, test the cable with a portable Ethernet cable tester to ensure that the RJ-45
plug (7) is correctly connected.
13. Carefully pull the cable slack back through the quick-disconnect assembly until the RJ-45 plug
(7) is almost touching the body (6). Adjust the cable position so that the RJ-45 Plug (7) fits
precisely into the RJ-45 cutout in the body (6), and press down the plastic tab so the plug fits
correctly.
14. Tighten the threads between sealing nut (1) and clamp ring (3) by hand, until the cable is
firmly anchored. Do not over tighten. Do not tighten with tools.

Installing cabling

According to your needs and local electrical codes and regulations, run Ethernet, body ground
wire, and any separate grounding wires as needed for antenna lightning arresters as described
in the respective Antenna Guide to where the E-MSM466-R will be installed. For the Ethernet cable,
allow for an extra 0.6 meters (two feet) for connector attachment and drip loops. Install an Ethernet
surge suppressor (not supplied) according to its instructions at the location where the Ethernet cable
enters the building. This may not be necessary if the outdoor cable run is very short, for example,
when the E-MSM466-R is mounted on an outdoor wall. The E-MSM466-R already includes a built-in
Ethernet suppressor for the other end of the Ethernet cable.
10
Installing
The next two steps should be performed by someone with experience building Ethernet