ASSEMBLY
7.
Assemble straight pipe (J) onto
swivel pipe (C), until you feel
light resistance. Hold swivel
pipe and turn straight pipe
clockwise, engaging positive
locking channels, until
connection is firm. Do not force
connection.
8.
Assemble straight pipe with
decal (K) to straight pipe (J) as
in step 7.
Note: Blower use will eventually
loosen pipe connections. Exclusive
positive locking system allows pipes to be
tightened. If loosening occurs, remove two
straight pipes and install according to
instructions 7 & 8.
PB-580T
Never perform maintenance or assembly procedures with
engine running or serious personal injury may result.

Install Blower Pipes

1.
Assemble clamps (A) and (G)
onto both ends of flexible pipe
(B).
Note: Clamp with cable guide
loop (G) fits elbow end of
flexible pipe.
20
C
G
G
B
© 12/2017 ECHO Inc.
PB-580H/T
J
K
mmp
G
X7505200705