SED encryption key management with ISKLM
The server supports self-encrypting drives (SEDs) and FIPS 140-2 drives as described in the
options
section. To effectively manage a large deployment of these drives in Lenovo servers, IBM Security
Key Lifecycle Manager (SKLM) offers a centralized key management solution. A Lenovo Feature on
Demand (FoD) upgrade is used to enable this SKLM support in the management processor of the server.
The following table lists the part numbers and feature codes for the upgrades.
Table 12. FoD upgrades for SKLM support
Part number
Feature code
Security Key Lifecycle Manager - FoD (United States, Canada, Asia Pacific, and Japan)
00D9998
A5U1
00D9999
AS6C
Security Key Lifecycle Manager - FoD (Latin America, Europe, Middle East, and Africa)
00FP648
A5U1
00FP649
AS6C

Controllers for internal storage

The SR860 supports internal SAS and SATA drives with the addition of a RAID adapter or HBA. For NVMe
support, the server offers two onboard NVMe ports on the processor and memory expansion tray (with
four processors) and two ports with the use of an NVMe Switch Adapter.
The following table lists the adapters used for the internal storage of the SR860 server.
Tip: Unlike System x RAID adapters, no upgrades are available for these RAID adapters. All supported
functions are included with the base part numbers.
Table 13. Controllers for internal storage
Part number Feature code Description
SAS/SATA HBA
7Y37A01088
AUNL
7Y37A01089
AUNM
RAID adapters
7Y37A01082
AUNG
7Y37A01083* AUNH*
7Y37A01084
AUNJ
7Y37A01085
AUNK
NVMe adapter
7Y37A01081
AUV2
* The RAID 730-8i is available in China only
The following table compares the functions of the storage adapters.
Lenovo ThinkSystem SR860 Server
Description
SKLM for System x/ThinkSystem w/SEDs - FoD per Install with 1 year S&S
SKLM for System x/ThinkSystem w/SEDs - FoD per Install with 3 year S&S
SKLM for System x/ThinkSystem w/SEDs - FoD per Install with 1 year S&S
SKLM for System x/ThinkSystem w/SEDs - FoD per Install with 3 year S&S
ThinkSystem 430-8i SAS/SATA 12Gb HBA
ThinkSystem 430-16i SAS/SATA 12Gb HBA
ThinkSystem RAID 530-8i PCIe 12Gb Adapter
ThinkSystem RAID 730-8i 1GB Cache PCIe 12Gb Adapter
ThinkSystem RAID 930-8i 2GB Flash PCIe 12Gb Adapter
ThinkSystem RAID 930-16i 4GB Flash PCIe 12Gb Adapter
ThinkSystem 1610-4P NVMe Switch Adapter
Internal drive
Number
Maximum
of ports
supported
8
2
16
1
8
2
8
2
8
2
16
1
4
2
22

Advertisement

Table of Contents