Specifications

Thermostat power requirements:
Humidity sensor and calibration:
Dehumidification setpoint range:
Occ, Stand-By and Unocc cooling setpoint range:
Occ, Stand-By and Unocc heating setpoint range:
Room and outdoor air temperature display range
Proportional band for room temperature control:
Agency Approvals Stand-Alone, BACnet & LON models
Agency Approvals Wireless models
THIS DEVICE COMPLIES WITH PART 15 OF THE FCC RULES. OPERATION IS SUBJECT TO THE FOLLOWING TWO
CONDITIONS: (1) THIS DEVICE MAY NOT CAUSE HARMFUL INTERFERENCE, AND (2) THIS DEVICE MUST ACCEPT
ANY INTERFERENCE RECEIVED, INCLUDING INTERFERENCE THAT MAY CAUSE UNDESIRED OPERATION.
Drawing & Dimensions
3.38" [86 mm]
Fig.13 – Thermostat dimensions
Operating conditions:
Storage conditions:
Temperature sensor:
Temperate sensor resolution:
Temperature control accuracy:
Humidity sensor precision:
Humidity sensor stability
Binary inputs:
Contact output rating:
Wire gauge
Dimensions:
Approximate shipping weight:
Agency Approvals all models:
4.94" [125 mm]
1.13" [29 mm]
19-30 Vac 50 or 60 Hz; 2 VA Class 2
0 °C to 50 °C ( 32 °F to 122 °F )
0% to 95% R.H. non-condensing
-30 °C to 50 °C ( -22 °F to 122 °F )
0% to 95% R.H. non-condensing
Local 10 K NTC thermistor
± 0.1 °C ( ± 0.2 °F )
± 0.5 ° C ( ± 0.9 °F ) @ 21 °C ( 70 °F ) typical calibrated
Single point calibrated bulk polymer type sensor
Reading range from 10-90 % R.H. non-condensing
10 to 20% precision is 10%
20% to 80% precision is 5%
80% to 90% precision is 10%
Less than 1.0 % yearly (typical drift)
30% to 95% R.H.
12.0 to 37.5 °C ( 54 to 100 °F )
4.5 °C to 32 °C ( 40 °F to 90 °F )
-40 °C to 50 °C ( -40 °F to 122 °F )
Cooling & Heating: 1.8°C ( 3.2°F )
Dry contact across terminal BI1, BI2 & UI3 to Scom
Fan relay output: 30 Vac, 1 Amp. Maximum, 3 Amp. in-rush
Valve triac output: 30 Vac, 1 Amp. Maximum, 3 Amp. in-rush
Valve analog: 0 to 10 Vdc into 2KΩ resistance min.
18 gauge maximum, 22 gauge recommended
4.94" x 3.38" x 1.13"
0.75 lb ( 0.34 kg )
UL: UL 873 (US) and CSA C22.2 No. 24 (Canada), File E27734
with CCN XAPX (US) and XAPX7 (Canada)
Industry Canada: ICES-003 (Canada)
FCC: Compliant to CFR 47, Part 15, Subpart B, Class A (US)
CE: EMC Directive 89/336/EEC (Europe Union)
C-Tick: AS/NZS CISPR 22 Compliant (Australia / New Zealand)
Supplier Code Number N10696
FCC: Compliant to: Part 15, Subpart C
Important Notice
All
VT7300
controls are for use as
operating controls only
and are not safety
devices.
These instruments have
undergone
rigorous
tests
verifications
prior
to
shipment
ensure proper and reliable operation in
the field. Whenever a control failure
could lead to personal injury and/or
loss of property, it becomes the
responsibility of the user / installer /
electrical
system
designer
incorporate safety devices ( such as
relays,
flow
switch,
protections,
etc...)
and/or
system to protect the entire system
against such catastrophic failures.
Tampering of the devices or miss
application of the device will void
warranty.
17
series
and
to
to
thermal
alarm

Advertisement

Table of Contents
loading

Table of Contents