Preparing furniture doors

Note:
When working on furniture doors, always observe
the following:
Select a furniture door thickness between at least 5/
8'' (16 mm) and 3/4'' (19 mm).
Always select a screw length which is shorter than the
thickness of the furniture door.
Always insert screws into the part of the furniture door
which is best able to handle the load.
Do not insert screws into fillings, etc.
Do not insert screws into filters, decorative strips, etc.
Protect the furniture door surfaces against damage
during installation.

Furniture door dimensions

Key
A
Furniture door protrusion
B
Lower edge of furniture door
The specified furniture door dimensions apply for a door
gap of
/
'' (4 mm).
5
32

Connecting the appliance

After installing the appliance, wait at least 8 hours until
starting up the appliance. During transportation the oil in
the compressor may have flowed into the refrigeration
system.
Before switching on the appliance for the first time, clean
the interior of the appliance (see chapter Cleaning the
appliance).

Electrical connection

,
WARNING:
Risk of electric shock!
,
WARNING:
Only insert the appliance into an earthed, 3-phase
outlet. Never remove the earth phase. Do not use
any adapters.Do not use any extension cables.
,
WARNING:
Incorrect connection of the appliance may result
in death, fire or electric shock. Improper
connection of the protective conductor may result
in electric shock. If you are in doubt as to whether
the appliance has been properly earthed, have it
tested by a qualified electrician or Customer
Service technician.
Do not use extension cables or distributors. This
appliance must be connected to a permanently installed
outlet.
The outlet must be in the vicinity of the appliance and be
freely accessible even after the appliance has been
installed.
The appliance complies with protection class I. Connect
it to a correctly installed outlet. Correct means: with a
protective conductor, 110 V – 120 V/60 Hz alternating
current. The outlet must be fused with a 10 A – 16 A
fuse.
The appliance comes with a UL-registered, 3-wire power
cord. The appliance requires a 3-pole outlet.
Please observe the following table with regard to this:
Appliance
Maximum simultaneous load
Refrigerator-freezer
6 A
Check on the rating plate whether the indicated voltage
and current type correspond with the values of your
power supply. The location of the rating plate can be
found in the Customer Service chapter.
,
WARNING:
Never connect the appliance to electronic energy
saver plugs.
Our appliances can be used with mains and sine-
controlled inverters. Mains-controlled inverters are
used for photovoltaic systems which are
connected directly to the national grid. Sine-
controlled inverters must be used for isolated
applications (e.g. on ships or in mountain lodges)
which are not connected directly to the national
grid.