2.16.2 Command Rotation
Cut in upon termination of Starting Control.
Achieve capacity control by controlling the compressor rotation based on:
• Temperature difference between set and room temperature, ∆T.
• Limit Rotation.
• Defrost control.
2.16.3 Fuzzy Control
Based on temperature difference, ∆T, current fan speed setting & current indoor operating mode at every 30
seconds interval.
Temperature Difference
Condition 1
∆T
∆T
= T
- T
t
room
set
Use to set target for compressor frequency change
Compressor frequency is increased or decreased
25
a Hz
(Time, s)
(Time, s)
38 (60)
52 (120)
35 (60)
55 (120)
55 (120)
70 (200)
40 (180)
54 (420)
40 (180)
54 (420)
(Applicable for ARXN/RXN50/60L)
Condition 2
d∆T
d∆T
= ∆T
t
t
b Hz
c Hz
(Time, s)
66 (120)
75 (360)
85 (470)
72 (180)
72 (180)
- ∆T
t-1
d Hz
Max Hz
(Time, s)
(Time, s)
80 (120)
94 (120)
-
-
-
-
90 (120)
-
90 (120)
-