ABSORPTION REFRIGERATORS
FOR LP-GAS AND ELECTRIC OPERATION
RM2410
RM2610
WARNING
This unit must be serviced by an
authorized serviceman. Modification
of the appliance can be extremely
could
hazardous and
lead to serious
injury or death.
FOR YOUR SAFETY
If
you smell gas:
1.
Open windows.
2. Don't touch electrical switches.
3. Extinguish any open flame.
4. lmmediately call your gas supplier.
FOR YOUR SAFETY
Do not store or use gasoline or other
flammable vapors and Iiquids in the
vicinity of this or any other appliance.
Models
RM2510
RM2810
INDEX
Installation
Operation
Maintenance &
. . .
Service
I
CET APPAREIL DOIT E T R EREPARE
SEULEMENT PAR UN REPARATEUR
AUTORISE. MODIFICATION DE
L'APPAREIL POURRAIT ETRE
EXTREMEMENT DANGEREUSE, ET
POURRAIT CAUSER MAL OU MORT.
f
IMPORTANT INSTRUCTIONS
READ CAREFULLY
Page
. . .
1-8
. . .
9-11
12-14
AVIS
M O D E L S -
RM2410
RM2510
RM2610
RM2810

Advertisement

Table of Contents
loading

Summary of Contents for Dometic RM2410

  • Page 1 ABSORPTION REFRIGERATORS FOR LP-GAS AND ELECTRIC OPERATION Models RM2510 RM2410 RM2810 RM2610 SERVICE OFFICE The Dometic Corp. 509 so. Poplar st. LaGrange, IN 46761 INDEX Page CANADA . . . Installation Dcmetic Distribution . . . Operation 9-11 866 Langs Drive Maintenance &...
  • Page 2: Section A. Installation

    SECTION A. INSTALLATION system kits, see separate list. The ventilation kits must 1. GENERAL INSTRUCTIONS be installed and used without modification. An opening toward the outside at floor level in the refrigerator This appliance is deslgned for storage of foods and compartment must be provided for ventilation of heavier- storage of frozen foods and making ice.
  • Page 3: Ventilation Heights

    REFRIGERATOR width and depth of the appliance. RM2410 The refrigerator must be installed in a substantial RM2510 lo87 enclosure and must be level. When installing the...
  • Page 4: Gas Connection

    Width Depth Depth Height refrigerator inch 33-1/2 22-53/64 24-1/2 32-7/32 21-1 7/32 23-19/32 32-7/16 21-1 3/1 l 6 24-3/32 1-1/4 RM2410 622.5 inch 40-29/32 22-53/64 24-1/2 40-3/32 21-1 7/32 23-19/32 40-5/1 6 21-13/1 l 6 24-3/32 1-1/4 RM2510 1039 622.5...
  • Page 5 REFRIGERATORS WITH PIEZO In case detailed instructions on the installation and IGNlTORS (MODEL RM2410) connection to the gas supply are required, contact your dealer or distributor. 9. GAS SAFETY SHUTOFF The gas safety shutoff must be tested after the refrigerator is connected to the LP Gas supply.
  • Page 6: Section B. Operating Instructions, Item 3, Gas Operation

    Clear Blue Color of Flame FIG. 8 Thermocouple RM2610 RM2810 Thermocouple Spring Thermocouple connection RM2510 No bubble should appear at the opening of the Refrigerators with Automatic Reignitors burner jet. Bubbles indicate a defective gas safety (RM2510, RM2610 & RM2810) shutoff and service is required.
  • Page 7 Table, on Page 7, for fuse size. three-prong receptacle. DO NOT cut off or remove the NOTE: The refrigerator Model RM2410 does not grounding prong from this plug. The free length of the have an automatic reignitor. The 3-way model has...
  • Page 8 CHANGING DOOR HINGES MAXIMUM TOTAL CONDUCTOR WIRE LENGTH IN FEET/METERS FROM ONE SIDE TO THE RM2410 RM2510 RM2610 RM2810 OTHER 9 ft. 7 ft. 6.5 tt 6.5 n 2.7 m 2.1 m (Refer to FIG. 12) Open the top door (or door on single door models) and remove the two screws holding the top 15 ft.
  • Page 9 Secure the decoration strip with the two screws removed in Step A(1). PANEL DIMENSIONS MAX. THICKNESS 5/32" (4mm) MODELS HEIGHT WIDTH TYPE MIN. MAX. MIN. RM2410 inch 27-7/16 27-23/64 20-9/32 20-13/64 RM2510 inch 35-5/16 35-15/64 20-9/32...
  • Page 10: Section B. Operating Instructions

    This will slow the circulation of hydrogen and ammonia gas, or in 2. CONTROLS Refrlgerators with Piezo lgnitors (RM2410): Refrigerators with Automatic Reignitors ON/OFF Switch (RM2510, RM2610 & RM2810) Thermostat Gas/Electric...
  • Page 11: Electric Operation

    When the thermostat reaches the set temperature, it will Refrigerators with Automatic Reignitors cut the burner back to bypass or, in electric operation, (RM2510, RM2610 & RM2810) shut off the heating element. To start the refrigerator, turn Knob ‘A’ to the ‘GAS The setting of the thermostat is not critical, but we position.
  • Page 12: Shut-Off / Storage Procedure

    Cleaning Ice making is accelerated if the thermostat knob ‘B’ is turned to the ‘MAX’ setting. It is a good To clean the interior lining of the refrigerator, use idea to do this a few hours before you require ice. lukewarm, weak soda solution.
  • Page 13: Section C. Maintenance And Service

    CAUTION 1. PERIODIC MAINTENANCE The following maintenance is required once To keep your Dometic refrigerator operating efficiently or twice a year, but should only be done by and safely, period inspection and cleaning of several a qualified serviceman who is familiar with LP components is recommended once or twice a year.
  • Page 14: Troubleshooting

    CAUTION CAUTION The safety shut-off must be manually DO NOT use a wire or pin when cleaning the depressed to allow gas pressure to flow to burner jet as damage can occur to the sure to the burner jet. Be apply the leak precision opening.
  • Page 15 ODOR FROM FUMES Remedies: Causes and All the instructions are to be followed closely. The The flame touches side of boiler due to dislocation refrigerator is quality-guaranteed. However, we are not of the burner. Relocate. Burner dislocation may also responsible for any failures caused by improper cause smoke and discoloring of walls and ceiling.