19 – VOICE ID MESSAGE RECORDING
The maximum recording time is 20s. If you choose Smart ID (function 15-2), this time will be split in
two, resulting in two 10s messages each. After sending the command, release PTT switch and the next
key up will be recorded and played back after recording. The voice ID time interval is the same as
function 14.
1 – Message 1 record
Ex: To record a message press: 1234191#
Note: Don't exceed the maximum time selected or the messages may become overlapped. Function 38
(Voice Message Lock) must be disabled in order to record the voice message or you will get an error
alert. Besides over the air recording, you can use an external source of audio by using the K1 audio jack.
Use the same commands like you would by on the air recording, but when pressing the PTT, the external
audio will be recorded instead.
20 – ALARM INPUT (Default = 0)
This alarm input is available for violation detection for windows, doors or repeater cabinet. Using any
kind of detector or sensor, a GND signal must be present all the time connected to alarm input (CN2-7)
in order to not trigger the alarm. If this ground signal is missing, the alarm will be triggered and stay in
alarm until a command is sent to turn it off. A siren sound will be transmitted over the air.
0 Disable
Note: Even with alarm activated the repeater will still be available for communication, but the siren
sound will return as soon as the communication ends.
21 – MONITOR INPUT (Default = 0)
A monitor input is available for lost AC voltage or logic state monitoring. When this input (CN2-8) is open
or high (5V), a short tone will precede the regular courtesy tone otherwise (low) nothing happens.
0 Disable
Note: Due to a pull-up resistor this input will be considered high if not connected.
22 – REPEATER PORT (Default = 1)
If disabled, the repeater will only accept signals coming from link port.
0 Disable
Note: This function only can be disabled if link port is enabled.
23 - LINK PORT (Default = 0)
0 – Disable
Signals from link port will be discarded
1 – Auxiliary
Allow access to repeater coming from another frequency (high priority)
2 – Control
Allow control access coming from another frequency (high priority)
3 – Link
Link operation (no hang time for signals coming through this port)
4 – Cross
Cross repeater operation
24 – TRANSMITTER TEST (Default = 0)
0 Disable
Note: This option has no time-out. Make sure your transmitter can stay keyed up for extended periods
without overheating. The tone frequency will be the same as simple courtesy tone (function 5)
1 Carrier
11
2 – Message 2 record
1 Enable
1 Enable
1 Enable
2 Carrier with Tone