KOMET 200 - 600 Contents Preface General notes Copyright Information regarding installation instruction Safety General notes on safety Notes on safety for the operation Safety notes for the operation with radio remote control ...
(e.g. safety or electrical) and environment protection regulations of the country in which the appliance is used also apply. All repairs on the appliances must be carried out by qualified persons. ELKA- Torantriebe GmbH u. Co. Betriebs KG accepts no liability for damage which is caused by using the appliance for purposes other than those for which it is built.
KOMET 200 - 600 1.1.1 Symbol explanation Remarks regarding the safety of persons and the gate opener itself are marked by special symbols. These remarks have to be absolutely observed in order to avoid accidents and material damage. DANGER! …points to an imminent dangerous situation, which can cause death or serious injuries if it is not avoided.
KOMET 200 - 600 Safety General notes on safety The valid regulations and standards have to be observed during installation and operation, e.g. DIN EN 13241-1, DIN EN 12445, DIN EN 12453 etc. Only the use of spare parts made by the original manufacturer is allowed. Do not put a defective gate opener / barrier into operation.
Page 7
KOMET 200 - 600 WARNING! Rotating and/or linear movable components can cause serious injuries. Do not reach into moving parts or handle any moving components during operation. Turn the appliance off before any maintenance work, repair work or other work and secure it against unintentional restarting.
In case of any damage record the type and extent on the delivery receipt or refuse acceptance. Inform ELKA-Torantriebe immediately in the event of damage. In case the above points are not observed claims will be denied due to insurance regulations.
KOMET 200 - 600 Installation information for partly completed machinery The partly completed machinery must not be put into service until the final machinery into which it has to be incorporated has been declared inconformity with the provisions of the machinery directive. The safety functions of the controller comply with EN ISO 13849-1:2008 Kat.2PLc/d.
KOMET 200 - 600 Usage The swing gate openers of series KOMET 200 - 600 are designed for gates moving horizontally and having low wind resistance. For max. width and weight of gate wing see table and diagram below. When usage is different from the above samples, please contact your supplier.
KOMET 200 - 600 Technical Data KOMET KOMET KOMET KOMET 200/202 280/282 400/402 600/602 one winged one winged one winged one winged gate/two gate/two gate/two gate/two winged gate winged gate winged gate winged gate Maximum width of wing * 2.000mm / 2.800mm / 4.000mm / 6.000mm /...
Page 13
KOMET 200 - 600 Maintenance The maintenance intervals must be decided individually as they are dependent on the frequency of use. We recommend maintenance at least once every 12 months. Table1 gates with low wind resistance depending on the installation dimensions (stroke) and the speed level depending on the installation dimensions **** A perfect fixation of the gate in position OPEN and CLOSED is only possible with external stops!
KOMET 200 - 600 Installation Installation dimensions (pivot point) All measurements are quoted in millimetre. The opener KOMET is for usage left and right. Drawing 3...
Page 16
KOMET 200 - 600 KOMET 200/280/400 approx. 100mm approx. 80mm 1010mm Drawing4 KOMET 600 approx. 100mm approx. 120mm 1245mm Drawing 5...
Page 17
KOMET 200 - 600 Mounting dimensions – Opening angles: Table of opening angels KOMET 200 depending on measurements A and Opening angle A / B * A / B * A / B * A / B * A / B * 90°...
240 / 150 Table 5 - (*All measurements are quoted in millimetre.) The measurement E for KOMET 200 / KOMET 280 / KOMET 400 is 1,010mm each, for the KOMET 600 it is 1,245mm. To exceed these measurements may result in a disruption of operation. To go below these measurements, reduces the opening angle.
KOMET 200 - 600 WARNING! The controller needs to be disconnected while welding is performed on the gate. Installation at the gate and gate post Drawing 7 Mounting support P Mounting support P with base plate (on side) 1. Secure the mounting support P on the gatepost at a height above the ground in which the mounting support T can also be secured properly on the gate.
KOMET 200 - 600 Drawing 9 4. Fit the gate opener with the joint bolts into the mounting supports P and T at gatepost and gate. Release the opener as described under 9. page 22 Now open and close the gate manually. Check if the gate can be moved the complete distance between the end positions easily.
Page 21
KOMET 200 - 600 Drawing 10 Internal stops 7. Replace and refit the opener to the mounting support T. Now connect the opener/s to the terminals of the controller MO 36. Connect the main wing to the terminal FAHR and the pedestrian wing to the terminal GEH. For one winged gates connect the wing to the terminal FAHR.
Page 22
KOMET 200 - 600 ATTENTION! The gate moves automatically during the next installation step. 19. During the following step the controller learns the running distance of the (one or two) gate wings. Push the button LERN. The controller sends the wing/wings into direction OPEN to the end stop and then into direction CLOSED to the end stop.
KOMET 200 - 600 Emergency release Emergency releasing Depending on the accessibility remove either the plastic cap on top or the one at the bottom of the gate opener. Place the wrench into the opening until it engages into the locking device (hexagon socket). Drawing 11 release engage...
KOMET 200 - 600 Controller MO 36 10.1 Electrical installation The leads must be inserted from below. For gates with two wings a minimum cross section [mm²] of the lead is necessary, which is determined by the length of the lead between the 2.opener and the controller. Cross sections selected too small will have adverse effect on the motor performance.
KOMET 200 - 600 10.2 Connections 10.2.1 Connection plan of the controller MO36 Each safety contact strip terminal which is not used has to be linked to an 8.2kΩ resistor. Each photo-cell and stop terminal which is not used has to be linked to a jumper.
Page 27
KOMET 200 - 600 Same function as external button BT Same function as external button BTG LERN Starting the learning mode Table 8 10.2.4 LEDs on the controller Mark Colour Function Desired value Yellow Lights when connected to main power Lights when safety contact profile SLA active Lights when safety contact...
KOMET 200 - 600 10.2.5 Output terminals Output Connection Corresponds to: Motor 5 pin Connection for 24Vdc motor and pulser for pedestrian the pedestrian wing wing and IMP Motor main 5 pin Connection for 24Vdc Motor and pulser for wing the main wing or for one-winged gates and IMP SCHLOSS...
Page 29
KOMET 200 - 600 Adjusting of end stops Learning of safety contact profiles and photo-cells connected Learning of running distance Adjusting of force and speed Adjusting of time lag of the pedestrian wing during closing Adjusting of time lag of main wing during opening ...
Page 30
KOMET 200 - 600 ATTENTION! During learning the safety devices may act different from the regular operation. Please ensure that no people are in the danger area during learning. After adjusting the end stoppers, push the button LERN to continue: The controller tests the safety contact strips and the photo-cells.
Page 31
Swing gate opener Adjustment range KOMET 200/202 F1 – F4 = max. 35 KOMET 280/282 F1 – F4 = max. 35 KOMET 400/402 F1 – F4 = max. 45 KOMET 600/602 F1 –...
Page 32
KOMET 200 - 600 Radio remote control code for MULTI can be learned or deleted Next Return to main sequence Table 15 Sub-sequence is activated with button LERN. The display shows: Display Corresponds to: The selected radio remote control code is deleted and another can be learned.
Page 33
KOMET 200 - 600 10.3.1.6 Sequence P6: Automatic closure for complete opening When sequence P6 is activated by button LERN, the present value for stay- open time for complete opening is displayed. Possible values are -- (not activated), 01 up to 299 (for 1s -299s). The value can be increased using button BT and decreased using button BTG.
Page 34
KOMET 200 - 600 10.3.1.7 Sequence P7: Automatic closure for pedestrian wing When sequence P7 is activated by button LERN, the present value for stay- open time for the pedestrian wing is displayed. Possible values are -- (not activated), 01 up to 299 (for1s - 299s). The value can be increased using button BT and decreased using button BTG.
Page 35
KOMET 200 - 600 10.3.1.8 Sequence P8: Warning prior to opening and closing When sequence P8 is activated by button LERN, the present value for warning time (opening and closing) is displayed. With the button BT the value can be selected (see table).Return to the learning sequence using button LERN.
Page 36
KOMET 200 - 600 Remains not Stops when Stops when moving interrupted, interrupted, opens when closes when free again free again Remains not Stops when Stops when moving interrupted, interrupted, opens when closes when free again free again Only closing Stops when No effect allowed...
Page 37
KOMET 200 - 600 10.3.1.10 Sequence PA: Photo-cell testing Prior to every gate movement a photocell test may be performed. The test consists of two phases. During the first phase the supply of the transmitters is switched off. The controller expects within the next 2.5 s that the receiver reports an obstacle.
Page 38
KOMET 200 - 600 Table 21 10.3.1.11 Sequence PB: Lockage function for the photo-cells Drawing 15 When using photo-cells in connection with the automatic closure for both wings, a lockage function is possible. To activate this function use the learning sequence.
Page 39
KOMET 200 - 600 Display Corresponds to: Pressure relief for electromagnetic bolt is deactivated. The gate wing pushes slowly (500ms min., but 1000ms max.) against the end stopper until the selected force is reached. The gate wing pushes slowly (500ms min., but 2000ms max.) against the end stopper until the selected force is reached.
Page 40
KOMET 200 - 600 10.3.1.15 Sequence PF: Return to original settings When sequence PF is activated by button LERN, re is displayed. To return to original settings, press and hold button BT and push button LERN. When only button LERN ispushed, you return to learning sequence without changing any values.
KOMET 200 - 600 10.4 Safety contact profiles for gate open (SLA) and close (SLZ) Gates with two wings: When a safety contact profile is activated, both motors react. The controller has two integrated detectors with testing function (according to EN954-1 category 2 for safety contact profiles with 8.2kOhm resistor) for gate OPEN and CLOSE.
KOMET 200 - 600 10.5 Additional modules 10.5.1 Timer module ASU2 (optional) The timer module can be plugged onto the controller. Function: When the timer has reached the set time for open, it sends an OPEN command to the controller. The gate cannot be closed as long as the timer is activated. After the open time has elapsed, the timer sends a CLOSE command to the controller.
KOMET 200 - 600 10.6 Power failure After power failure or disconnecting from mains the position of the wing/wings is unknown to the controller. The controller first works in a starting mode. The wings are moving slowly. A pressure relief of electromagnetic bolt occurs before every movement.
Page 44
KOMET 200 - 600 10.8 Emergency mode In case a safety device (LSA, LSI, SLA or SLZ) is faulty, emergency mode is possible. After a warning time of 10 seconds, the gate can be moved in an emergency mode by using BA or BZ (dead man’s function). During the warning time as well as during the emergency mode the warning light is flashing.
Page 45
KOMET 200 - 600 10.9 Parameter and Original settings Constant, not changeable values Parameter Original settings Time-lag before reactivating motor 500ms Reversing for a short distance on obstacle 500ms Time-lag before reversing 200ms Max. running time limit 500s Running time reserve during regular mode Warning time prior to emergency mode Table 29 Changeable values...
Page 46
KOMET 200 - 600 Radio remote control code BT X-Code - + - + - + - + - All other radio remote control codes X-Code deleted Table 30...
Page 47
KOMET 200 - 600 Index C N Connections ....... 24 Name plate ........9 Controller MO 36 ....19, 23 O D Original settings ......44 Declaration of incorporation ..8 P E Parameter ........44 Emergency mode ....... 43 Power failure .......