  • Page 1: Table Of Contents

    Installation and operating instructions Slide Gate Openers EST 204 – EST 404 - EST 804 Contents : Page Usage Technical Data Measurements Installation Emergency release and height adjustment Mounting the rack Electrical setup (Connection examples) MO 56/S controller for EST 204 / 404...
  • Page 2: Usage

    Usage The sliding gate openers EST 204 / 404 and EST 804 are designed for horizontal moving gates either running on a rail, or cantilever types. Please take note of the valid safety regulations. Technical Data EST 204 EST 404...
  • Page 3: Installation

    Adjustment of the motor Motorholder, the height holder + or - 15 mm to the shaft middle is possible ca. 87 mm on delivery © 09.02.2006 ELKA-Torantriebe GmbH u. Co. Betriebs KG page 3 EST 204, EST 404, EST 804...
  • Page 4: Mounting The Rack

    Check that the rack is correctly mounted and that all screws are tight. The emergency release must work at every position of the gate. © 09.02.2006 ELKA-Torantriebe GmbH u. Co. Betriebs KG page 4 EST 204, EST 404, EST 804...
  • Page 5: Electrical Setup (Connection Examples)

    During the learning mode the gate may move automatically several times. Ensure nobody will enter the gate area. The opener is ready for use. Connection example EST 204 / 404 Connection example EST 804 © 09.02.2006 ELKA-Torantriebe GmbH u. Co. Betriebs KG page 5 EST 204, EST 404, EST 804...
  • Page 6: Mo 56/S Controller For Est 204 / 404

    MO 56/S controller for EST 204 / 404 Red light / warning light 3 min light Green light Hall-Sensor Motor 24Vdc Learn-button Diag. Serial button 14V 0V Sync Transformer 0V 14V Receiver 1 Transm.1 0V 14V Receiver 2-6 Transm.2-6 8.1. Input terminals MO 56/S...
  • Page 7: Operating Modes Mo56 (Dip Switches)

    Prior to every movement the photocells are tested. The gate can only move when photocells are without malfunction. Caution: The number of photocells has to be stored before using the test.(cha. 9.6) © 09.02.2006 ELKA-Torantriebe GmbH u. Co. Betriebs KG page 7 EST 204, EST 404, EST 804...
  • Page 8: Safety Functions Mo56

    LS-S + - 14Vac LS-E + - 14Vac After this please check every single photocell MO56 for proper function. © 09.02.2006 ELKA-Torantriebe GmbH u. Co. Betriebs KG page 8 EST 204, EST 404, EST 804...
  • Page 9: Learn Mode Mo56

    Exit learn mode without changes After each alteration the controller exits to operation mode. After altering the DIP switch mode confirm with the button LERN © 09.02.2006 ELKA-Torantriebe GmbH u. Co. Betriebs KG page 9 EST 204, EST 404, EST 804...
  • Page 10 Press the LERN button. The gate closes and the BTG position is stored. After this procedure the controller returns to normal operation mode by itself. Note: The running time must have been stored already. © 09.02.2006 ELKA-Torantriebe GmbH u. Co. Betriebs KG page 10 EST 204, EST 404, EST 804...
  • Page 11: After Power Break / Emergency Mode

    Pulse creator (Hall IC) in the motor or cable between motor and controller faulty. 9 flashes Measuring amplifier faulty. Send the controller back to your dealer. © 09.02.2006 ELKA-Torantriebe GmbH u. Co. Betriebs KG page 11 EST 204, EST 404, EST 804...
  • Page 12: Mo 43 Controller For Est 804

    The button for opening has no effect in this case. Radio Socket for radio remote receiver EKX1BE. L1, N Mains 230V ac Earth © 09.02.2006 ELKA-Torantriebe GmbH u. Co. Betriebs KG page 12 EST 204, EST 404, EST 804...
  • Page 13: Operating Modes Mo43 (Dip Switches)

    Radio remote control does not work in this mode. Safety equipment and the limits of movement are still effective. Switch 6 off: The control box works with locking relays. © 09.02.2006 ELKA-Torantriebe GmbH u. Co. Betriebs KG page 13 EST 204, EST 404, EST 804...
  • Page 14 If the gate is closed, then it will only open after the second signal. The normal operating cycle is in effect. © 09.02.2006 ELKA-Torantriebe GmbH u. Co. Betriebs KG page 14 EST 204, EST 404, EST 804...
  • Page 15: Setting Personal Code For Radio Remote

    2.) You can now allocate the second button to the garage door opener by going through the procedure described in the installation instructions for the garage door opener in the paragraph ‘Learning personal code’. © 09.02.2006 ELKA-Torantriebe GmbH u. Co. Betriebs KG page 15 EST 204, EST 404, EST 804...
  • Page 16: General Notes To Safety

    All alterations or extensions to the appliance must be carried out with parts which ELKA Torantriebe GmbH & Co. Betriebs KG have defined as suitable for such alterations, and be carried out by qualified personnel.