  • Page 1: Table Of Contents

    Installation and Operating Instructions Slide Gate Openers EST 4004K Contents Page Usage Technical data Measurements Installation Emergency release Electrical connections Connection example MO 44-2 Controller 7.1. Connections 7.2. Operating mode 7.3. Programming Timer module (optional) Fault codes Setting personal code General notes to safety ©06.03.06ELKA-Torantriebe GmbH &...
  • Page 2: Usage

    The OPEN button can also be transmitted to a further control box (e.g. for a barrier). Optional timer card for automatic switching between day and night operation. 3. Measurements © 27.04.2005 ELKA-Torantriebe GmbH u. Co. Betriebs KG Page 2 EST 4004K...
  • Page 3: Installation

    The rack and the pinion should fit together with minimum play but enough to ensure that the pinion does not carry the gate. mark here © 27.04.2005 ELKA-Torantriebe GmbH u. Co. Betriebs KG Page 3 EST 4004K...
  • Page 4: Emergency Release

    10 % reserve and the power required are saved. The opener is ready for use. Carry on setting operating mode as described in section 7.2. © 27.04.2005 ELKA-Torantriebe GmbH u. Co. Betriebs KG Page 4 EST 4004K...
  • Page 5: Connection Example

    6. Connection example © 27.04.2005 ELKA-Torantriebe GmbH u. Co. Betriebs KG Page 5 EST 4004K...
  • Page 6: Mo 44-2 Controller

    7. MO 44-2 Controller loop 13NO 13NO A1 STOP START 14NO 14NO A2 © 27.04.2005 ELKA-Torantriebe GmbH u. Co. Betriebs KG Page 6 EST 4004K...
  • Page 7: Connections

    (electronic brake). The gate can only move again when BS is released and a new signal is given. Push button for serial switching OPEN-STOP-CLOSE-STOP (n.o.). The LED BT lights when BT or the corresponding remote button is pressed (see automatic closure, too). © 27.04.2005 ELKA-Torantriebe GmbH u. Co. Betriebs KG Page 7 EST 4004K...
  • Page 8: Operating Mode

    DIP A3 ON The closing gate stops when the photo-cell is interrupted and carries on closing when the DIP A4 OFF photo-cell is free. The opening gate is not effected. © 27.04.2005 ELKA-Torantriebe GmbH u. Co. Betriebs KG Page 8 EST 4004K...
  • Page 9 If the gate is opening and BZ is pressed, the signal is stored until the gate is open and then carried out. Three-phase operation DIP B5 OFF Drive with single-phase motor (with electronic brake) DIP B5 ON Three-phase motor (with reversing contactor and mechanical brake) © 27.04.2005 ELKA-Torantriebe GmbH u. Co. Betriebs KG Page 9 EST 4004K...
  • Page 10 If during part two the obstacle is still being reported (the controller assumes a real obstacle being present), the gate will not move. No error code is shown. © 27.04.2005 ELKA-Torantriebe GmbH u. Co. Betriebs KG Page 10...
  • Page 11: Programming

    When the time required has elapsed press BTG again. The time is stored and the controller is ready for use. The time is only effective when automatic closure is on (DIP A5 ON). © 27.04.2005 ELKA-Torantriebe GmbH u. Co. Betriebs KG Page 11 EST 4004K...
  • Page 12: Timer Module (Optional)

    The gate closes Switches on The gate closes, night operation is forced Switches off The gate opens, day operation is continued Doesn’t matter Does not affect the gate © 27.04.2005 ELKA-Torantriebe GmbH u. Co. Betriebs KG Page 12 EST 4004K...
  • Page 13: Fault Codes

    Example B) Receivers without code switches : Logic boards MO 34, MO44 or MO 55 These receivers learn the code from the transmitter as described in the paragraph ‘Learning personal code’ in these installation instructions. © 27.04.2005 ELKA-Torantriebe GmbH u. Co. Betriebs KG Page 13 EST 4004K...
  • Page 14: General Notes To Safety

    All alterations or extensions to the appliance must be carried out with parts which ELKA Torantriebe GmbH & Co. Betriebs KG have defined as suitable for such alterations, and be carried out by qualified personnel.