CDX-E410
3.2 Timer function
The unit setted in this RX timer function is playbacked at the setting time as the ON-TIME.
It functions even when at setted time the system is already in power on state or the unit is already playbacked.
(1) Timer play
The state is not changed if the setted unit is already in the state of playback.
RX unit
[Standby state]
Power supply through AC OUTLET
POWER_ON command [CD state is
neither PORT_PLAY nor PORT_STOP]
PLAY command [CD state isn' t
PORT_PLAY]
After sending POWER_ON command, if CD unit has Auto-play function after power-on, RX will not send PLAY
command.
28
CD unit
Wait "ON" setting
[Power shut down]
time
Power on process
PORT_PRE_STANDBY
PORT_STANDBY
Switch input function to unit
setted in timer function
PORT_STOP
PORT_PLAY
[Standby state] [Power on] [Play state]
Reset start
initialize process
Initialize complete
Power on process
Play process