• motor nominal frequency (parameter
FREQ)
Set the maximum value for external reference REF1
(parameter
1105
REF1 MAX).
Set constant speeds (drive output frequencies) 1, 2 and 3
(parameters
1202
CONST SPEED 1,
and
1204
CONST SPEED 3).
Set the minimum value (%) corresponding to the minimum
signal for AI(1) (parameter
Set the maximum limit for the drive output frequency
(parameter
2008
MAXIMUM FREQ).
Select the motor stop function (parameter
FUNCTION).
Check the direction of the motor rotation.
• Turn the potentiometer fully counterclockwise.
• If the drive is in remote control (REM shown on the left),
switch to local control by pressing
• Press
to start the motor.
• Turn the potentiometer slightly clockwise until the motor
rotates.
• Check that the actual direction of the motor is the same as
indicated on the display (FWD means forward and REV
reverse).
• Press
to stop the motor.
9907
1203
1301
MINIMUM AI1).
2102
DIRECTION OF THE MOTOR ROTATION
.
LOC
REM
MOTOR NOM
CONST SPEED 2
STOP
9907
LOC
PAR
FWD
1105
LOC
PAR
FWD
1202
LOC
PAR
FWD
1203
LOC
PAR
FWD
1204
LOC
PAR
FWD
1301
LOC
PAR
FWD
2008
LOC
PAR
FWD
2102
LOC
PAR
FWD
2102
LOC
PAR
FWD
Start-up and control with I/O