Panasonic CS-MC120KE Service Manual page 14

Multi-split air conditioner
Table of Contents

Advertisement

CS-MC120KE
Operation Details
Automatic Fan Speed Mode
When Automatic Fan Speed is selected at Remote Control during cooling operation.
• Fan speed rotates in the range of Hi to Me.
• Deodorizing Control.
Indoor
Fan
Comp.
* 1 Fan Speed is Hi until the compressor stops (when the room temperature reaches
setting temperature).
* 2 Fan Speed is Me after the compressor restarts.
Cooling Operation Time Diagram
Set Temp.
Basic Time
Compressor
Indoor Fan
Outdoor Fan
Operation LED
<Description of operation>
d – g
g – h
h – 0
q – t
. .
. .
1
Lo
stop
stop
40"
30"
ON
Intake Air
Temperature
a b c d e f g h i j k l m n o p q r s t u v w x y z
Comp.
ON
1.5˚C
Comp.
OFF
1'
:
Time Delay Safety Control (waiting for 3 minutes)
:
60 sec. Forced Operation
:
7 min. Time Saved Control
:
Anti Freezing Control
Lo
Lo
Lo
stop
stop
20"
160"
40"
30"
OFF
ON
Indoor
10°C
Heat
Exchanger
Temp.
2°C
3'
1'
7'
1'
<Condition>
a – h
h – p
p – w
– 13 –
. .
. .
2
4'
3'
:
When outdoor temperature is high
:
When outdoor temperature is moderate
:
When outdoor temperature is low
Operation
Stop

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cu-mc240ke

Table of Contents