ADTRAN TRACER User Manual page 41

Hide thumbs Also See for TRACER:
Table of Contents

Advertisement

61280.003L1-1B
VT-100 U
I
SER
The Tracer may be accessed with a VT-100 compatible terminal
set to 9600 bits per second, 8 data bits, and no parity, connected
to the RS-232 port on the back of the unit. Once a terminal is
connected, pressing the ESC key will present the System Status
screen. If password access has been enabled, then press "Enter"
or "Return" in order to see the "Enter Password:" message. Tracer
is shipped with password protection disabled.
RS-232 I
NTERFACE
The Tracer has an RS-232 interface for system management via an
attached VT-100 terminal, personal computer, or modem. The
RS-232 port is configured as a DCE with the following pin
assignments:
C
C
ABLE
ONNECTIONS
The cable connections required for various configurations are
detailed in Appendix A of this manual.
4/12/99
NTERFACE
Signal
Name
TXD .................. 2 ............... To Tracer
RXD .................. 3 ............... From Tracer
RTS ................... 4 ............... To Tracer
CTS ................... 5 ............... From Tracer
DSR .................. 6 ............... From Tracer
Ground ............. 7
S
3
ECTION
Pin
Number
Direction
P
AGE
O
PERATION
31