Maintenance 
Cleaning 
To clean the lens use compressed air to clear dust and other particles, then carefully clean with a 
wet cotton swab. The cotton swab should be moistened with clean water. 
To clean the meter housing, wipe with a damp, soft cloth. Do not use solvents or abrasives. Do 
not immerse the IR300UV in water or other liquid. 
Replacing Batteries 
When the battery icon indicates a low battery, or when the meter 
doesn't switch ON, replace the batteries. 
The battery compartment lid is located on the rear of the handle. 
Remove the one Philips head screw and lift the lid off. 
Replace the three 1.5V AA batteries following correct polarity and then 
replace and secure the battery compartment lid. 
Battery Safety Notes: Please dispose of batteries responsibly; never dispose of 
batteries in a fire, batteries may explode or leak. If the meter is not to be used 
for 60 days or more, remove the battery and store separately. Do not mix 
battery types or freshness levels; please use batteries of the same type and of the same freshness level. 
Never dispose of used batteries or rechargeable batteries in household waste. 
As consumers, users are legally required to take used batteries to appropriate collection sites, the 
retail store where the batteries were purchased, or wherever batteries are sold. 
Disposal: Do not dispose of this instrument in household waste. The user is obligated to take end‐of‐life 
devices to a designated collection point for the disposal of electrical and electronic equipment.  
Specifications 
Infrared Thermometer Specifications 
Range / Resolution 
Accuracy 
Response Time 
Repeatability (% of reading) 
Emissivity 
Temp. Coefficient 
Field of View 
Laser power 
Spectral response 
o
‐30~500
C (‐22~932
 0°C:   ±1.5°C or 1.5% of reading (whichever is greater) 
 32°F:   ±3°F or 1.5% of reading (whichever is greater) 
 ‐10°C to 0°C:   ±2°C 
14° to 32°F:   ±4°F 
Note: Accuracy is specified for the ambient temperature range: 
21~25°C (70~77°F) 
500ms (95% of reading) 
±8% of reading or ±1.0°C (1.8°F) whichever is greater 
Adjustable from 0.10 to 1.00 
0.1°C/°C or ±0.1%/°C of reading (whichever is greater) 
D/S = Approx. 12:1 ratio (D = distance, S = spot) 
Less than 1mW 
8 to 14 microns 
9
                                              IR300UV‐en‐GB_V1.0   1/16 