Thank you for choosing a Sirius product. S-DD2-L FLUSH TOP DOWNDRAFT INSTALLATION INSTRUCTIONS FOR SEM 1, SEM 2, SEM 7, & SEM 8 motors SDD2 L EMTC 580 EAN #9351116001063 SDD2 L EMTC 880 EAN #9351116001094 SDD2 L EMTC 1180 EAN #9351116001193...
S-DD2-L FLUSH TOP INSTALLATION GUIDE TO THE ATTENTION OF THE USER INSTALLATION GUIDELINES APPLIANCE DIAGRAMS PRE-INSTALLATION CHECKS INSTALLING THE RANGEHOOD INSTALLATION INSTRUCTIONS FOR SEM 1 AND SEM 2 150MM SIDE OR BOTTOM VENTING FOR SEM 7 AND SEM 8 200MM SIDE OR BOTTOM VENTING FOR SEM 1, SEM 2, SEM 7, AND SEM 8 150MM / 200MM FRONT OR REAR VENTING DUCTING FROM MOTOR TO VENT (SEM 1 &...
S-DD2-L FLUSH TOP INSTALLATION GUIDE TO THE ATTENTION OF THE USER INSTALLATION GUIDELINES FOR GAS COOKTOP APPLICATIONS This rangehood is designed to work with ducted outside evacuation. • A minimum 50mm gap must be left between the stainless steel frame and the nearest edge of the cooktop.
S-DD2-L FLUSH TOP INSTALLATION GUIDE APPLIANCE DIAGRAMS DUCTING TYPES • Side / bottom venting - SEM 1, SEM 2 motor pg.7 • Side / bottom venting - SEM 7, SEM 8 motor pg.8 • Front / rear venting - SEM 1, SEM 2, SEM 7, SEM 8 motor pg.10 •...
S-DD2-L FLUSH TOP INSTALLATION GUIDE PRE-INSTALLATION CHECKS Connect all of the electrical components to the unit and motor to make sure both the unit and the motor are functioning properly. (NOTE: The motor plug is fitted with a dummy plug - with the exception of SEM1 motor - to protect the connection from dust.
S-DD2-L FLUSH TOP INSTALLATION GUIDE INSTALLING THE RANGEHOOD STEP 1: Refer to cutout dimensions required per unit as they • Before carrying out the appliance installation, vary for each unit. please check that all components are not damaged, in such a case contact your retailer and do not carry out any installation operation.
S-DD2-L FLUSH TOP INSTALLATION GUIDE INSTALLATION INSTRUCTIONS SIDE OR BOTTOM VENTING (For front or rear venting instructions, see pages 10-12) STEP 2: STEP 3: 1. Remove front 150mm or 200mm adaptor plate 1. Remove side or bottom cover plate (Part C). (Part ‘D’) (Fig.
S-DD2-L FLUSH TOP INSTALLATION GUIDE STEP 5: • Connect rectangular to round adaptor (Part ‘A’) to air outlet (Part ‘B’), (Fig. 6). • Secure both ends with duct tape (Fig. 6) STEP 6A: Ducting to SEM 1 motor (150mm ducting) This step covers ducting for SDD2 L EMTC 580 models only.
S-DD2-L FLUSH TOP INSTALLATION GUIDE STEP 6B: Ducting to SEM 7 motor (200mm ducting) This step covers ducting for SDD2 L EMTC 880 and 1180mm models. For the 580mm model, see Step 6A. For SEM 8 motor with SDD2 L EMTC 880/1180 - 200mm option only. 1B: Connect a duct expander (Part ‘H’) to rectangular to round adapter (Part ‘A’), then connect length of ducting (Part ‘K.2’) to the 200mm outlet.
S-DD2-L FLUSH TOP INSTALLATION GUIDE INSTALLATION INSTRUCTIONS FOR SEM 1, SEM 2, SEM 7, SEM 8 FRONT OR REAR VENTING (For side or bottom venting instructions, see pages 7 - 9) STEP 2: If venting from front, check to see if front adaptor plate (Part ‘D’) is attached.
Page 11
S-DD2-L FLUSH TOP INSTALLATION GUIDE STEP 4: 1. Use 150mm ducting (Part ‘K.1’) for S-DD2-L-EMTC 580 versions or 200mm ducting (Part ‘K.2’) for S-DD2-L-EMTC 880 and 1180 versions. 2. The ducting fits directly onto the collar on the front adaptor plate (Part ‘D’). 3.
S-DD2-L FLUSH TOP INSTALLATION GUIDE DUCTING FROM MOTOR TO WALL VENT: (SEM 1 and SEM 8) 1. Run the length of ducting to the motor. (Additional lengths of ducting can be attached using an additional internal connector pieces.) NOTE: No connector required as it connects directly to the collar of the motor. 2.
Page 13
S-DD2-L FLUSH TOP INSTALLATION GUIDE ELECTRICAL CONNECTION DANGER NOTE If the rangehood presents any anomaly, This appliance complies with the European disconnect the appliance or remove the Directives 2006/95/EC (Low Voltage fuse corresponding to the appliance Directive) and 2004/108/EC (Electromagnetic power disconnecting line.
S-DD2-L FLUSH TOP INSTALLATION GUIDE HOW THE RANGEHOOD WORKS Light On/Off Decrease fan Fan speed Increase fan 10 min shut-off speed indicators speed timer Light ON/OFF key Automatic turn off: After 4 hours of continuous working from the The light switches on and off only when the carriage last setup, the appliance turns off and closes is fully OPEN.
S-DD2-L FLUSH TOP INSTALLATION GUIDE CLEANING THE RANGEHOOD Careful maintenance ensures proper operation and good performances over time. CAUTION The hood must be disconnected from the electrical network, both by unplugging the appliance from the socket and activating the magnetic circuit breaker (safety cut-out), before removing the metal grease filters.
S-DD2-L FLUSH TOP INSTALLATION GUIDE REPLACING THE LIGHT 1. Lift the unit, then press the red button on the 2. Remove the two screw under the top panel, and power transformer - cutting power to the unit. the three on the back (five screws in total). 3.
S-DD2-L FLUSH TOP INSTALLATION GUIDE AFTER SALES SERVICE Any maintenance operation on your appliance should NOTE be carried out by: • Either Arisit Pty Ltd; When calling, please mention the appliance • Or a qualified professional technician, authorized details: Production date, (Fig. 9A), Type (Fig. 9B) for that brand if out of warranty.
Page 18
S-DD2-L FLUSH TOP INSTALLATION GUIDE PARTS LIST - INCLUDED PIECES PART A PART B Rectangular to round ducting adaptor Bottom/side cover collar SPS-81020 PART C PART D Bottom/side exit connector Front/rear vent adaptor SPS-20059120071 PART E PART F Front/rear vent cover plate Upright fixing brackets SPS-75059000082...
Page 19
S-DD2-L FLUSH TOP INSTALLATION GUIDE PARTS LIST - OPTIONAL PIECES To be purchased separately PART G PART H Universal ring clamp 150mm to 200mm Duct expander URC25-215/325 GDR 150/200 PART I PART J 150mm diameter connector piece 200mm diameter connector piece GDC-150 GDC-200 Part K.1 / K.2...
S-DD2-L FLUSH TOP INSTALLATION GUIDE WIRING DIAGRAMS www.arisit.com ARISIT PTY LIMITED (Australia) Sirius Hoods and ducting products are only available from our select group of Sirius Professional Stockists ABN 23 091 515 294 nationwide. For the latest list of Sirius Stockists www.arisitwarranties.com.au 40-44 Mark Anthony Drive near you, please refer to...