Touch
to return to the Home screen.
DIFF (Used for 2 stage normal or heat pump with auxiliary only, not on screen for single stage)
The differential is the number of degrees between the room temperature and the Target Temperature
at which the 2nd stage will be used. Default is 2°F.
Touch MENU and then DIFF. Use the arrows to set the DIFF.
Recommend 2°F for very cold climates and the 4°F for warm climates.

MANUAL Screen Functions

The CT100 has 4 manual override commands. The manual screen is accessed by touching the large
current temperature display in the middle of the HOME screen.
IMPORTANT: The Mode must be in HEAT or COOL to access the manual screen.
TEMPORARY override Touch the + / - arrows to select your desired temporary Target Temperature.
Touch HOME to return to operation. The TEMPORARY icon will display indicating you have modified
the Target Temperature for the current Time Slot only. It goes back to the program target at the next
period. Also, when in TEMPORARY, if the target is set the same as the programmed target for that
period, the word TEMPORARY will go out.