8369H-English_Manuals 10/2/14 10:19 AM Page 9
Manual mode LED:
Light On: Manual mode is on and laser can be turned on with
compensator locked
Light Off: Manual mode is off
Note: When manual mode is on, the laser does not self-level and
no out-of-level alarm is indicated.
Compensator Lock and Power On/Off Switch:
Turn the switch up, the laser is on, and the power LED is on.
Turn the switch down, the laser is off, the power LED is off.
Pulse Mode:
Push the pulse mode button to turn on. The pulse LED light will be lit
and the laser line will be dim. The laser can be used with the
40-6780 detector (not included) when the pulse mode is on.
Push the pulse mode button again to turn off the pulse mode.
The pulse LED light will not be lit and the laser line brightness will
be normal.
Manual Mode:
Press the manual mode button with the transportation lock knob in
the "Locked" position. The power LED will light and the manual
mode LED will flash. The instrument is now in the manual mode.
Note: When manual mode is on, the laser does not self-level and
no out-of-level alarm is indicated.
Press the manual mode button again and the instrument will power off.
©2014 Johnson Level & Tool