7.8.5.1 Status of Photo Level / Switch
1. Photo level at gain 0 should satisfy the criteria.
Photo number
Criteria
PC22
> 20
If it is out of criteria, take actions considering cable disconnection, part failure, contamination, optical
axis shift.
Minimum level is at the gain 00 and it becomes larger in accordance with the gain and maximum is
"FF".
If level is not displayed and level will not be changed even lit by flashlight, light receiving section has
issue. If level varies, light emitting section has problem.
2. Judgment of the photos and switches
Switch name
I/L (Inter Lock)
L/L (Lower Level)
F/L (Feed Level)
IPC
Sensor
PC11、PC20、PC21、
PC22、PC31、PC41、
PC42、PC43、PC51、
PC52
(1) Specify parameters and click the "RUN" button.
・Photo gain:All gain(default)
・Lamp mode1:Light on(default))
・Lamp mode2:Light off (default)
・LED:ON(default)
・Hopper position:F/L(default)
If necessary, change parameter and perform this.
(2) Level of each photos will be displayed every 2
To fix the screen, click the "Pause" button.
To finish display, click the "FINISH" button.
Note
Exclude
PC22DBL
Check by closing/opening the front part of the device.
Elevator operation / Detect by specifying UP (L/L).
Elevator operation / Detect by specifying UP (F/L).
Or lift the Pickunit by hands.
NONE
Confirm condition by blocking light with paper or finger.
second
Switch operation
REV0 2010.02.15
Close: "0"
L/L="1"
F/L="1"
Normal
condition
Blight: "1"
Dark: "0"