Fisher & Paykel DE4024P Installation Instructions & User Manual page 13

Table of Contents

Advertisement

Available languages

Available languages

Electrical connection information for electric dryers
For electrical connections using a power cord:
Fire Hazard
Use a new UL-listed 240V 30 amp dryer power supply cord with closed
ring terminals or spade terminals with upturned ends.
Use a UL-listed strain relief.
Disconnect power before making electrical connections.
Connect neutral wire (white or center wire) to center terminal.
Ground wire (green or bare wire) must be connected to green ground
connector.
Connect remaining two supply wires to remaining two terminals.
Securely tighten all electrical connections.
Replace the terminal block cover.
Failure to do so can result in death, fire or electrical shock.
Grounding instructions
For a grounded, cord-connected dryer:
This dryer must be grounded. In the event of a malfunction or breakdown, grounding
will reduce the risk of electric shock by providing a path of least resistance for electric
current. This dryer uses a cord having an equipment-grounding conductor and a
grounding plug. The plug must be plugged into an appropriate outlet that is properly
installed and grounded in accordance with all local codes and ordinances.
WARNING!
Improper connection of the equipment-grounding conductor can result in a risk
of electric shock. Check with a qualified electrician, or service representative or
personnel, if you are in doubt as to whether the appliance is properly grounded.
DO NOT modify the plug on the power supply cord. If it will not fit the outlet, have a
proper outlet installed by a qualified electrician.
SAVE THESE INSTRUCTIONS
INSTALLATION INSTRUCTIONS
WARNING!
!
EN
11