SI1000 SERIES DISPLAY UNIT
user and installation manual

Advertisement

Table of Contents
loading

Summary of Contents for Ametek SI1500

  • Page 1 SI1000 SERIES DISPLAY UNIT user and installation manual...
  • Page 2: Table Of Contents

    Layout of Rear Panel SI1500 ........
  • Page 3: Safety Summary

    1.0 Safety Summary Terms in this Manual WARNING statements identify conditions or practices that could result in personal injury or loss of life. CAUTION statements identify conditions or practices that could result in damage to the equipment or other property. Symbols in this Manual This symbol indicates where applicable cautionary or other information is to be found.
  • Page 4: Service And Repair

    2.0 Service and Repair This equipment contains no user serviceable parts. This equipment must be returned to your Solartron dealer for any service and repair. The SI1000 is designed to be maintenance free. Contact with solvents should be avoided. Any attempt to dismantle any of the SI1000 will invalidate the warranty. The SI1000 series are precision instruments and should be handled with care.
  • Page 5: Installation Into A Panel

    3.0 Installation into a Panel - Ensure that there is sufficient space behind the relevant instrument panel for the SI1000 and its cabling Cut out the panel aperture to the dimensions shown. Working from behind the panel, with the box fully located, fit the side brackets to the studs and slide them forward toward the panel until they lock into place.
  • Page 6 3.0 Installation into a Panel (cont) CAUTION: Do not over tighten the screws as this may damage the case of the instrument. WARNING: On installing or removing the SI1000, you must be aware of any hazardous equipment or materials in the vicinity. Make sure that any equipment into which the SI1000 system is to be installed is switched off and made safe.
  • Page 7: General Description

    4.0 General Description 4.1 OVERVIEW The SI1000 series of readouts provides a simple way of using Solartron transducers. All of the basic metrology functions are provided within this small robust instrument. 4.2 SPECIFICATION See the Product data Sheet 502892 4.0 General Description 502893 issue 4.1...
  • Page 8: Display Panel And Connections

    5.0 Display Panel and Connections 5.1 FRONT AND REAR PANEL LAYOUTS Range Lamps Mode Key ◄ UP and Hold Key ▲ 7 digit Red Display Down and Zero Key or Preset Key ▼ Set Key ► 5.0 Display Panel and Connections 502893 issue 4.1...
  • Page 9: Layout Of Rear Panel Si1500

    5.0 Display Panel and Connections (cont) 5.1.1 Layout of Rear Panel SI1500 RS232 and RS485 Connection Analogue Outputs 4-20 mA or VOLT Digital Probe (Orbit Input) High/Middle/Low Alarm Output Zero Input Hold/Peak+/Peak-/Diff input 24 VDC Input 5.1.2 Layout of Rear Panel SI1300...
  • Page 10: Layout Of Rear Panel Si1100

    5.0 Display Panel and Connections (cont) 5.1.3 Layout of Rear Panel SI1100 RS232 and RS485 Connection Analogue Outputs: 4-20 mA or VOLT LVDT Transducer Input Transducer Zero Adjustment Transducer Gain Adjustment High/Middle/Low Alarm Output Zero Input Hold/Peak+/Peak-/Diff input 24 VDC Input 5.0 Display Panel and Connections 502893 issue 4.1...
  • Page 11: Connection Details

    5.0 Display Panel and Connections (cont) 5.2 CONNECTION DETAILS - SI1500 +24V DC Power OUTPUTS RS485 RS232 Volts 4-20mA 0V DC Power Relay Common Relay High Limit Relay OK limit INPUTS RELAY POWER Relay Low Limit Input Relay Common ORBIT...
  • Page 12 5.0 Display Panel and Connections (cont) 5.2 CONNECTION DETAILS - SI1300 +24V DC Power R S485 R S 232 0V DC Power Relay Common Relay High Limit Relay OK limit IN P U T S IN P U T S R E LA Y P O W E R V olts...
  • Page 13 5.0 Display Panel and Connections (cont) 5.2 CONNECTION DETAILS - SI1100 +24V DC Power OUTPUTS RS485 RS232 Volts 4-20mA 0V DC Power Relay Common Relay High Limit LVDT Relay OK limit ZERO GAIN INPUTS RELAY POWER Relay Low Limit LVDT INPUT Input Relay Common Zero Input Relay...
  • Page 14: Set Up Options

    6.0 Set Up Options 6.1 MAIN MENU OVERVIEW Menu Parameter Setting Range 0.1dP Set decimal point position. nnnnnnn. To nn.nnnnn 02.St Hi Set High Alarm 0099.9999 to -099.9999 03.St Lo Set Low Alarm 0099.9999 to -099.9999 04.St0db Set Relay Hysteresis Time 0.1 to 9,9 seconds 05SE AL Switch Relay On or OFF...
  • Page 15 6.0 Set Up Options (cont) Menu Parameter Setting Range 09.St CO Select RS232 or RS485 RS232 / RS485 10 bPS Set Communication protocol 4800 / 9600 / 38400 / 115200 Data Bits (8), Parity (None) Stop Bits (1) 11Addr Set Communication address 1 - 99 12StoUt Set Analogue Output Signal...
  • Page 16 6.0 Set Up Options (cont) Menu Parameter Setting Range 17rEAL Show Real value (Probe absolute Reading) 18Unit Select Units mm / inches 19StAn9 Select calibration On / Off 20CAL HI Set Scale maximum Set the Display Maximum Reading 21CALLo Set scale minimum Set the Display Minimum Reading 22ACAL Set Calibration...
  • Page 17: Menu Setup Detail

    6.0 Set Up Options (cont) 6.2 MENU SETUP DETAIL 01. dP nnnn.nnn 04.St0db 07SE1 nP Hold nnnnn.nn nnn.nnnn Hold Peak - P 02.St Hi 0000.000 05SE AL 08Ho ldt 0000.001 0000.000 0000.000 06.bEEP 09.St CO rS-232 03.St Lo 0000.000 rS-232 RS-485 0000.000 0000.001...
  • Page 18 6.0 Set Up Options (cont) 10 bPS 9600 9600 19200 11Addr 10Addr 12StoUt nonE 11StInp 0-10 SI1100 SI1300 nonE 10. -10 0-10 4-20 SI1500 12H “Er 6.0 Set Up Options 502893 issue 4.1...
  • Page 19 6.0 Set Up Options (cont) 13H ZEr 16OFFD 0000.000 19StAn9 0000.000 0000.001 0000.000 14H 1 nP 20CAL HI Only if 18SAn9 = ON 17rEAL 4.321 15dir EHtEn 18Unit EHtEn rEtrAct Inch 6.0 Set Up Options 502893 issue 4.1...
  • Page 20: Calibration Menu

    6.0 Set Up Options (cont) 6.3 CALIBRATION MENU 6.3.1 Set the Maximum Reading to the Maximum Sensor Output Set the Display Range 20CAL HI 0000.000 to the maximum 0099.999 to value for the Digital – 0099.999 Probe 0000.000 0000.001 Eg DP2 =2.0 Eg Set Max Value to 2 0000.000...
  • Page 21: Set The Minimum Reading To The Minimum Sensor Output

    6.0 Set Up Options (cont) 6.3.2 Set the Minimum Reading to the Minimum Sensor Output Set the Display Range 21CALLo 0000.000 to the maximum 0099.999 to value for the Digital – 0099.999 Probe 0000.000 0000.001 Eg DP2 =0 Eg Set Max Value to 0 0000.000 0000.000...
  • Page 22: Calibrate The Maximum And Minimum

    6.0 Set Up Options (cont) 6.3.3 Calibrate the Maximum and Minimum 22ACAL H 1.000 SWITCH BETWEEN HIGH AND H !.000 L 1000 LOW CALIBRATION POSITIONS SI1500: DP MAX H 16383 COUNT=16383 CALIBRATE HIGH POSITION (PROBE H !.000 SI1100: LVDT VOLTAGE UP...
  • Page 23: Functions

    7.0 Functions 7:1 Zero Function The Zero position is remembered by the SI1000 series even after a power cycle To put the SI1000 readouts into absolute mode, find the probe true zero position (mid stroke for an LVDT) or fully out for a Digital Probe. Zero at this position.
  • Page 24: Peak Function

    7.0 Functions 7:3 Peak Function 0 7 S E 1 n P P e a k P D IS P L A Y F O L L O W S P R O B E 1 .2 3 4 5 P ro b e = 1 .2 3 4 5 P R E S S T O A C T IV A T E...
  • Page 25: Input Relays

    7.0 Functions 7:4 Input Relays ZERO RELAY Close Zero Relay (PIN 8 and PIN 7) >100mS ZERO DISPLAY Release Relay HOLD PEAK-P PEAK-N DIFF MODE RELAY Select Mode Menu 7 Close Hold Relay (PIN 9 and PIN 7) SI1000 will activate HOLD or PEAK-P or PEAK-N or DIFF (as selected Menu 7) Right Display Digit will pulse SI1000 will remain in MODE all time relay closed Right Display Digit will pulse...
  • Page 26: Communication Protocol

    < or = or> XXXXXXXX 0D 0A Example SI1500 Display 0.504 OK (Middle lamp) To SI1500 “<R”,”01”,”=”,” chr$(13),chr$(10)” From SI1500 “>R”, “01”, “=” , “+000.504”,chr4(13),chr$(10) Alarm High/Low Value Reading Input Format Command (2 Bytes) ID (2 Bytes) End Code (2 Bytes) <S 0D 0A 8.0 Communication Protocol...
  • Page 27 End Code (2 Bytes) Bytes) >S XXXXXXXX,XXXXXXXX 0D 0A Example SI1500 Display High Alarm Value 0.500 Low Alarm value -0.005 To SI1500 “<S”,”01”,”=”,” chr$(13),chr$(10)” From SI1500 “>S”, “01”, “=” , “+000.500,-000.500”,chr$(13),chr$(10) 8.0 Communication Protocol (RS232 and RS485) 502893 issue 4.1...
  • Page 28: Appendix A Units Supplied With Power Supply

    Appendix A - Units Supplied with Power Supply Appendix A - Units Supplied with Power Supply 502893 issue 4.1...