1MRS758267
COM600 series 5.0
Cyber Security Deployment Guideline
Figure 5.4-1 WSUS Wizard, Choose Upstream Server
4. In the Specify Proxy Server section of the configuration wizard, specify any
intermediary proxy settings to connect to internet, and click Next.
5. In the subsequent section, click Start Connecting to verify the connection to
Microsoft Update Server. Once the connection is verified, click Next. If not, double
check the internet connection in the local machine and proxy settings.
6. In the Choose Languages section, select Download updates only in these languages
and click English.
7. In the Choose Products section, click on the products specified below, based on
the COM600 product version being used, see Table A2-1.
Table A2-1 Microsoft Product for COM600 version
COM600 Product Version
COM600 v4.1
WSUS_Wizard_Choose_Upstream_Server.png
Products chosen in WSUS Configuration
1. Developer Tools, Runtimes, and
Redistributables
1.1. Visual Studio 2005
1.2. Visual Studio 2010
1.3. Visual Studio 2012
2. Windows
2.1. Windows Embedded Standard 7
39