• are enabled in the scanner. See the Product Reference Guide
(PRG) for more about configuring the scanner to read symbolo-
gies).
Is the bar code displayed but not entered?
The bar code is displayed on the host device correctly, but you still
have to press a key to enter it (the Enter/Return or Tab key, for
example).
You need to program a suffix which enables the scanner to output
the bar code data plus the key you need (such as a carriage return
"CR") to enter the data into your application. Refer to the PRG
for further information.
Does the scanner read the bar code incorrectly?
If the scanner reads a bar code, but the data is not displayed cor-
rectly on the host screen:
• The scanner may not be programmed for the appropriate termi-
nal interface. For example, you scan "12345" and the host dis-
plays "@es%." Reprogram the scanner with the correct interface
selection bar code. See the Product Reference Guide (PRG).
• The scanner may not be programmed to output your bar code
data properly. For example, you scan "12345" and the host dis-
plays "A12345B." Reprogram the scanner with the proper Data
Editing selections. Reference the PRG.
The scanner won't read your bar code at all.
• Scan the part number bar code on the back of this manual or
other known-good bar code samples. If the scanner reads sample
bar codes, check that your target bar code is readable.
• Verify that your bar code symbology is enabled. See the PRG.
If you aren't sure what programming options have been set in the
scanner, or if you want the factory default settings restored, go to
the
Resetting the Standard Product Defaults
and scan the standard factory default settings bar code.