FACTORY DEFAULTS

Master Programming CodeWWW..WWWWWWW.W.W...123456
Entry Code LengthWWWWWWWWWWWWWWW.WW..4 digits
Entry ModeWW..WWWWWWWWWWWWWW.W...Card or PIN
Request-to-exit Output RelayWWWWWWWWW...........No Output
Alarm Shunt OutputW.WWWWWWWWWWWWW.........Disabled
Forced Entry OutputWWWWWWWWWWW..WWWW..No Output
Door Ajar OutputWWWWWWWWWWWWW..WW.W...No Output
Main Relay On TimeWWWWWWWWWWWWW..W..02 Seconds
Auxiliary Relay On TimeWWWWWWWWWWW.....W02 Seconds
Solid State Output #3 On TimeWWWWWWWWW......02 Seconds
Solid State Output #4 On TimeWWWWWWWWWW..02 Seconds
Door Sense/Inhibit InputWWWWWWWWWW...WW..Door Sense
Keypad Lockout OutputWWWWWWWWWWWW..WW.Disabled
Keypad Active OutputWWWWWWWWWWWW..W..W..Disabled
Beeper Sounds When Key PressedWWWWWWWW...WWWYes
Beeper Sounds During Relay #1WWWWWWWWW..W...WW.No
Beeper Sounds During Relay #2WWWWWWWWWWW...W...No
Beeper Sounds During Output #3WWWWWWWWWWW .....No
Beeper Sounds During Output #4WWWWWWWWWWW........No
Keypad Lockout CountWWW.WWW......W.3 Tries Before Lockout
Anti-Passback TimeWWWWWW..WW...WWW.No Anti-Passback
Auto-RelockWWWWWWWWWWWWW...WWWW.WWWW.On

BASIC PROGRAMMING

When the 924P EntryCheck™ is in Programming Mode the yellow
indicator will blink slowly. After a programming command is
selected, the yellow indicator will flash rapidly while the keypad is
waiting for user input data. The green indicator will light if the data
is accepted. The red indicator will light if any programming data is
entered incorrectly, and the command will have to be fully re-
entered.
Entering Programming Mode
The 6-digit Master Programming Code (default = 123456) is used
to enter Programming Mode.
Press: # 9 # Master Code #
Master Code = the current 6-digit Master Programming Code
Exiting Programming Mode
The red indicator will light after exiting Programming Mode
Note: The 924P will automatically exit Programming Mode after
two minutes of inactivity
Re-entering a Command After a Mistake
If the red indicator lights, signaling an incorrect entry, or an
incorrect key is pressed during programming, to clear the keypad
and re-enter the command:
Press:
Setting Entry Code Length
Press: 03 # Length #
Length = 4-6 for entry code length
Note: If the Entry Code Length is going to be changed from the factory
default of 4 digits, make this change first before programming any entry
codes.
Select Entry Mode
Sets the entry mode for the 924P.
Press: 05 # Mode #
Mode=Operating Mode(1-3)
1=Card or PIN; 2=Card Only 3=Card and PIN
P:\INSTALLATION INST\Access Controls\INST-924\INST-924P.vsd
Press:
**
#
*
9 #
Default: 4 digits
Default: Card or PIN
Rev C
10-14
Adding a New User
User PIN Only Access (No Card)
Press: 01 # User # Code # Code # Relay #
User Card and or PIN Access
Press: 06 # User # Code # Code # Relay # Present Card
User=User number to be added: 001-500
Code=The new entry code: 1-999999, depending on code length
Relay=Relay output entry code will activate:
1=Main Relay 2=Auxiliary Relay 3=Both Relays
10=Relay #1, toggled 20=Relay #2, toggled 30=both Relays toggled
12=Relay #1 toggled; Relay #2 timed open
21=Relay #1 timed open; Relay #2 toggled
The yellow indicator will flash quickly while the 924P stores the new
user information in memory The green indicator will light when the
new code and card are accepted. If the user number already exists
or an entry error has been made, the red indicator will light. Delete
the user and re-enter the new information again.
Note: Leading zeros (zeros before the code number, i.e.0001) do not need to
be entered when programming a new code. The 924P will internally add any
zeros to fill digits determined by the entry code length setting. Leading zeros
will have to be entered by the user when entering their code to gain access.
Output Toggle Mode
When an output is programmed for Toggle Mode, the output
alternates from OFF to ON or from ON to OFF each time it is
accessed. When an output is toggled on, the green LED remains
solid until toggled off.
The rules for a toggle output are:
If the output is OFF, it will turn ON and stay on until the next
activation.
If the output is ON, it will turn OFF and stay off until the next
activation.
An authorized PIN, Card, or REX input programmed to
momentarily activate that same relay will reset the relay to its
normal state.
Adding Multiple Sequential Cards
st
Press: 08 # 1
Number of users = Total number of consecutive cards to add
The yellow indicator will flash quickly while the 924P erases the
user from memory. The green indicator will light when the codes
have been added.
Adding Multiple Non-Sequential Cards
st
Press: 07 # 1
# Present 1
Number of users = Total number of consecutive cards to add
The yellow indicator will flash quickly while the 924P erases the
user from memory. The green indicator will light when the codes
have been added.
Erasing a Single User
User =The user number to delete 002-500
The yellow indicator will flash quickly while the 924P erases the
user from memory. The green indicator will light when the code is
erased.
Page 5
---- Or ----
User # Code # Code # Relay # Number of users
st
# Present 1
card
st
1
User =Starting user number to add
User # Code # Code # Relay # Number of users
st
nd
card, Present 2
card, G, Present last card
st
1
User =Starting user number to add
Press: 02 # User # User #