Assembly Of The Operator And Sliding Arm Da149 To The Opening Side - Abloy DA461 Installation And Commissioning Manual

Swing
Table of Contents

Advertisement

7.4

Assembly of the operator and sliding arm DA149 to the opening side

Y
L
Frame
Arm distance
depth
< 100
100-200
Y
Frame depth
Pre-setting of the spring force
- After installation, ensure that the arm and door are properly
- Mount a door stop to the door open position so that wind
- Tighten the holding screw.
Mounting of the operator: M6x14 and washer
Minimum door
L/mm
width M/mm
90
700
170
800
34
Frame
depth
adjusted.
will not drive the door against the wall, resulting in damage.
585
M
Y
Length of
extension piece
44 No extension piece M8x20 +
54 10 mm (DA150/01) M8x30 +
64 20 mm (DA150/02) M8x35 +
1. Mount the arm to the operator
2. Teach door open position 44°-55° (see page 18)
3. Remove the arm
4. Turn mode switch to OPEN
5. Close the door and mount the arm to the operator and
to the sliding rail
6. Teach door closed and open positions again
DA104
Min 14
Max 20
Mounting
of the arm
washer
washer
washer
13