03

Testing the Hall generator's power supply

Disconnect the Hall generator's connector.
Ignition on
A voltage of 12 Volt +- 1 V must be
measurable between pin 1 (positive) and pin
3
(negative). If this is not the case, check the
wiring with reference to the circuit diagram.
03 - 28
Maintenance, Self-diagnosis

Error code 1141

Error code 1141 draws attention to an error
in
the area of the DME control unit. If this error
code appears, the DME control unit must be
replaced.