Summary of Contents for Morsø S100-12

  • Page 1 The Morsø S100 Series Instructions for use 1-22 Fitting Instructions 23-49 www.morsoe.com...
  • Page 2: Table Of Contents

    Contents 2. Insert types These instructions describe the function of the fireplace inserts listed below: Introduction......................2 Insert types......................3-12 /ONE-SIDED Functional elements................... 13 Morsø S100-12 Operations handle....................13 Fuel..........................14 Special instructions..................14-15 Width (inbuilt) 1196 mm Air supply........................16 Height (inbuilt) 1168-1368 mm Using for the first time..................16...
  • Page 3 /ONE-SIDED /ONE-SIDED Morsø S101-11 Morsø S101-12 Width (inbuilt) 795 mm Width (inbuilt) 805 mm Height (inbuilt) 1305-1505 mm Height (inbuilt) 1339-1539 mm Depth (inbuilt) 537 mm Depth (inbuilt) 602 mm Weight 135 kg Weight 156 kg Output 10 kW Output 10 kW Flue pipe Ø180 mm...
  • Page 4 /TWO-SIDED /TWO-SIDED Morsø S120-21 Morsø S120-22 Width (inbuilt) 773 mm Bredde (indbyg.) 800 mm Height (inbuilt) 1124-1324 mm Width (inbuilt) 800 mm Depth (inbuilt) 511 mm Height (inbuilt) 1125-1325 mm Weight 130 kg Depth (inbuilt) 537 mm Output 10 kW Weight 129 kg Flue pipe...
  • Page 5 /TWO-SIDED /CORNER Morsø S122-22 Morsø S140-41 Width (inbuilt) 963 mm Width (inbuilt) 613 mm Height (inbuilt) 1358-1558 mm Height (inbuilt) 1290-1490 mm Depth (inbuilt) 543 mm Depth (inbuilt) 613 mm Weight 264 kg Weight 109 kg Output 10 kW Output 7 kW Flue pipe Ø180 mm...
  • Page 6 /CORNER /THREE-SIDED Morsø S140-42 Morsø S160-32 Width (inbuilt) 674 mm Width (inbuilt) 550 mm Height (inbuilt) 1290-1490 mm Height (inbuilt) 1395-1525 mm Depth (inbuilt) 674 mm Depth (inbuilt) 912 mm Weight 157 kg Weight 258 kg Output 7 kW Output 12.6 kW Flue pipe Ø180 mm...
  • Page 7: Functional Elements

    3. Functional elements /THREE-SIDED Morsø S161-32 The S100 series is known for being extremely easy to use. Width (inbuilt) 550 mm Height (inbuilt) 1395-1525 mm Grill to convection air top Depth (inbuilt) 700 mm Weight 217 kg Output 10 kW Flue pipe Ø180 mm Fresh air pipe...
  • Page 8: Morsø S100-12

    • Only spare parts expressly approved by the manufacturer may be used. Maximum amount of wood: • If necessary, please contact your dealer. Morsø S100-12 3.4 kg/hour • No structural changes must be made to the inserts! Morsø S101-11 and S101-12 3.2 kg/hour...
  • Page 9: Air Supply

    7. Air supply in the installation room 9. Lighting the fire The insert only functions properly when there is sufficient combustion air in the instal- For correct and safe use of your insert, make sure that the chimney has sufficient lation room.
  • Page 10: Adding Wood

    • Cleaning the glass: 11. Adding wood •Open the door slowly to prevent turbulence/underpressure and smoke being drawn out into the room. The correct time to add new fuel is when the wood in the combustion chamber has burnt down to embers. •Add the fuel and close the door.
  • Page 11: Sliding Door

    17. Sliding door - ball bearing guide 19. What information does your installer/dealer need? The ball bearing guide must be lubricated at least once a • If your fireplace inset develops a fault, your installer will need the following data: year.
  • Page 12: Guarantee

    20. Guarantee The guarantee is only valid if the assembly and handing over of the unit is undertaken by a specialist dealer and all applicable building regulations have been complied with. For your Austroflamm fireplace inset we guarantee perfect function of the body for 6 years, and 2 years for all other steel and cast-iron parts from the date of first purchase.
  • Page 13 Contents 1. General 1. General ........................... 25 1.1. Rules to be followed 1.1. Rules to be followed ......................25 1.2. Pre-fitting checks ........................25 (Basic requirements) 1.3. Sliding door ..........................26 1.4. Setting up the insert ......................26 o Installation standard DIN 18895 1.5. Positioning the insert ......................26 o Installation standard DIN 18896 1.6.
  • Page 14: Sliding Door

    This is a fire risk! For the S100-12 and S122-22, there is a transport securing screw on both sides. The 1.5. Positioning the insert procedure is as above.
  • Page 15: Removing The Chamotte Securing Device

    For the S160-32 and S161-32, there are 2 transport securing screws fitted towards the 1.9 Fitting the smoke plates in Morsø inserts back. All insets are supplied with chamotte smoke plates which are packed separately and must be fitted in the insets. See the fitting instructions in the tables below. Morsø...
  • Page 16: Requirements Regarding The Room, Chimney And Fresh Air Connection

    2. Requirements regarding the room, chimney and fresh air connection for the insert Morsø S122-22 Morsø S100-12 The insert must not be placed in Position the smoke plates as shown in the Position the smoke plates as shown in the illustration below.
  • Page 17: Combustion Air Pipe

    Models S100-12 and S122-22 only The fresh air pipe can be fitted on both the right and left side.
  • Page 18: Connection Pieces/Flue

    2.5 Connection pieces/Flue 4.1. Minimum diameters The connection pieces/flue must be dimensioned to DIN EN 13384. They must be steel pipe with a min. thickness of 2 mm. Austenitic, stainless steel needs to be only 1 mm thick. The connection piece is connected directly to the chimney. The connection piece inside the fireplace structure must be min.
  • Page 19: Heat Insulation

    4.2 Heat insulation 5. Installation requirements IMPORTANT: Insulation must comprise heat insulation plates/elements of class A1 in accordance with DIN 4102 part 1 with a utility temperature limit of 700 °C and a density of more The fireplace inset must not be in contact with the cabinet (min. distance 3 mm), as this can damage the unit! than 80 kg / m³.
  • Page 20: Installation In Front Of Or To The Side Of A Wall To Be Protected

    5.4. Heat insulation on the side and back wall 5.2. Installation in front of or to the side of a wall to be protected (All values in accordance with Promasil 950 KS) 2 Insulation layer (Flue) • The front walling (22) and building’s wall (20) must be protected with a layer of insu- 3 Connection piece lation (4,16) to the back and side of the fireplace.
  • Page 21: Expansion Seams

    5.7. Expansion seams 5.12. Ceiling above the Insert - There must be NO contact/connection between the inset and the lining (11)! There- fore, all places of contact between the inset and lining must be shielded with a sealing cord (Glass fibre). - If the cavity above the fireplace inset reaches up to the ceiling The support frame (23) must not rest on the insert or be screwed or welded to it! (8), it must be protected, if:...
  • Page 22: Information On Maintenance/Repair

    6. Information on maintenance/repair Converting the opening from right to left-sided 6.1. Folding door inset - Fitting the door 1. Fit the door in the open position 2. First hang the door in front of the sto- ve push the top bolt into the opening. Remove the spring Lift off the door 3.
  • Page 23: Sliding Door Insert - Fitting The Door

    6.2. Sliding door inserts - Fitting the door 6.3 Converting the radiation frame to right opening of the door (Fitting the door in the reverse order) IMPORTANT: The radiation frame must be rotaded 180° in the door (the horizontal part must always be at the bottom), otherwise this can affect the secondary air supply, which impars combustion and can cause soot to form on the glass For fireplace insets S100, S101, S120, S121 and S122...
  • Page 24: Type Plate Location

    For insert Morsø S140 6.3. Type plate location The type plate can be found under the middle stone in the base of the stove (or un- der the ash drawer).
  • Page 25 6.4. Combustion Place the chamotte parts without mortar in the order illustrated For models: S100 and S101 1. Log catch 2. Base front 3. Base left 4. Base right 5. Intermediate plate 6. Back wall 7. Side wall 8. Z-plate left 9.

Table of Contents