117/200/234 VAC Operation
The Commander VHF-2000 comes factory wired for 234 VAC operation.
For best operation, you should use a dedicated 234 VAC main capable of
supplying 20 Amps of peak AC current. Unless for Export or user specified
all VHF-1200 Amps. are wired for 117 VAC.
All Commander Amplifiers manufactured for export are wired for 234 vac
or 200 vac depending on the final destination.
To convert the VHF-1200 to 234 VAC operation, remove the rear panel
connector cover located on the top left hand
SURE YOU HAVE REMOVED THE LINE CORD PLUG FROM YOUR
WALL SOCKET. IF YOU FAIL TO UNPLUG YOUR AMPLIFIER, YOU
WILL EXPOSE YOURSELF TO LETHAL VOLTAGES.
has been removed, do the following steps:
1. Loosen the screws and remove the jumper wire going from the terminal
block position 1 to 3. See illustration.
2. Unscrew and remove jumper connection at terminal block position 5
and place it at terminal block position 3. Secure all screws.
illustration.
3. Replace rear panel connector cover
4. Remove the 117 volt plug and replace with an appropriate 3 prong 234
VAC 20Amp plug.
corner. CAUTION.... BE
After the cover
See