Table of Contents Before Installation ................................... Exemption from Liability ..............................Safety and Instruction Signs in the Manual ....................Safety ..........................................Electric Voltage Hazard Warning ..........................Accident Hazard Warning ..............................Warnings Related to the Use of Solar Modules ..................Warnings Related to the Installation of Solar Modules ..............
Any other application is ing and operating the LG Solar modules. not conventional. Please read this manual carefully before installation. All installation and safety in-...
Page 4
Safety Safety Electric Voltage Hazard Warning The following safety instructions and Accident prevention guidelines, rules and regulations issued by the organisa- statutory directives must be observed tions and authorities concerned apply to and adhered to. installation, operation and maintenance. If applicable, observe the national and Installation and maintenance may only regional directives, in particular the fire be carried out by qualified persons and...
Safety Observe the special safety directives on Do not insert any part in the connector handling direct current and photovoltaic plugs or jacks. systems. The solar modules always generate direct current when exposed Do not carry out any work in wet weather to sunlight.
Safety Accident Hazard Warning The following safety instructions and Do not touch the glass and rear side of statutory directives must be observed the solar module with bare hands. Wear and adhered to. safety gloves to avoid injuries. Installation and maintenance may only The glass surface and module frame be carried out by qualified persons and can heat up under the sun’s rays, which...
Safety Warnings Related to the Use of Solar Modules The following safety instructions and The solar modules may not be oper- statutory directives must be observed ated in a location where they could come and adhered to. in contact with salt water. Persons who have no knowledge of solar Ensure that no inflammable gases could modules or, for instance, the measures...
Safety Warnings Related to the Installation of Solar Modules The following safety instructions and Do not dismantle the solar module and statutory directives must be observed never carry out any unauthorised and adhered to. changes on the solar module. Do not remove any labels.
Use only solar modules of the same type accessibility is expected. in a combined connection. For more information on solar modules from LG Electronics, please refer to the da- tasheets of the solar modules. These can be found at www.lg-solar.com. In particular ambient conditions, a solar...
Electrical Installation Series Connection The maximum system voltage must not the solar modules can be mounted be exceeded. simply and quickly The solar modules can be connected in higher voltages make it possible to series to receive a higher output voltage. have smaller cable cross-sections Series connection is preferred if the sys- higher voltages lead to lower currents...
At its factory, LG Electronics have been taken for blocking the reverse pre-installs bypass diodes in the solar current; meaning, for instance fuses to modules.
Page 12
For more information on solar modules from module clamps. LG Electronics, please refer to the data sheets of the solar modules. The data Solar modules from LG Electronics can sheets can be found at www.lg-solar.com.
Mechanical Installation Mounting with Mounting Holes in the Module Frame Do not remove the frame of the solar The solar module can be fastened to a module. Do not modify the module frame, mounting system using the four mount- e. g. by adding holes, since this may ing holes at the bottom of the module damage the solar module and compro- frame.
Mechanical Installation Mounting with Module Clamps on the middle module clamps between the solar Longer Module Side modules. Using suitable module clamps, ensure that measurements A, B and C are Alternatively, the solar modules can be observed in line with the following graphic. fastened to the mounting system with module clamps.
Page 15
Mechanical Installation Position the module clamps uniformly If you are mounting several solar modules on the solar module in accordance with next to each other, place a distance piece the following graphic. In doing so, ensure between adjacent solar modules. The that D is not below 170 mm and does not solar modules should never be mounted exceed 400 mm.
Mechanical Installation Mounting with Module Clamps on the Position the module clamps uniformly Shorter Module Side on the solar module in accordance with the following graphic. In doing so, ensure The solar modules can also be fastened that D is not below 150 mm and does to the mounting system with module not exceed 270 mm.
Mounting with Inlay Systems If you are mounting several module series consecutively use middle module clamps Solar modules from LG Electronics can between the solar modules. The solar also be installed with suitable inlay sys- modules may never be mounted directly tems.
Earth Ground Wiring Earth Ground Wiring Screws or other earth ground connec- Description Basic size Material tions may not be used for fastening the Hexagonal screw M4 × 15 rust-free photovoltaic system mechanically on the Shim rust-free load-bearing surfaces or frames. Serrated washer rust-free Earth ground wire...
Maintenance and Inspection Maintenance and Disposal Inspection The LG solar modules may only be serviced Please contact us at the address given and maintained by qualified persons. overleaf if you have any queries related to the disposal or recycling of solar modules Do not clean the glass surface with an from LG Electronics.
Page 20
Product specifications are subject to change without notice. LG, LG logo and Life’s Good are trademarks of LG Electronics, Inc. worldwide. Trademarks and intellectual properties of LG Electronics, Inc. are protected by international copyright laws. -V2-201012 Frage an LGE: Gibt es eine neue Nummer? Dann bitte mitteilen...