User:
User R:
User G:
User B:
6500:
9300:
Saturation:
Color Temp.
x
y
Tolerance
Note: x1, y1 should meet the color chromaticity of white in panel specification.
2.7 POWER SUPPLY: PK100V0140I OR PK100V0180I
2.7.1 Input Voltage Range
The monitor shall operate within specification over the range of 100 to 240 VAC power supply.
2.7.2 Input Frequency Range
Input power frequency range shall be from 47.5 to 63 Hz over the specified input
voltage range.
2.7.3 Quick specification review
•
Input current: 1.5A (max) at 90VAC input and full load ,
•
Inrush current @ cold start
•
Output
Output Volt
•
Total output power:
•
Withstanding voltage :
•
Leakage current :
•
Efficiency :
Red signal gain by user defined.
Green signal gain by user define.
Blue signal gain by user defined.
set CIE coordinate at 6500°K color temperature (when use 6500°k
color temperature, contrast display cannot change and cannot adjust).
set CIE coordinate at 9300°K color temperature (when use 9300°k
color temperature, contrast display cannot change and cannot adjust).
Color saturation adjustment, the range from 0 to 100. (Def. 100)
9300
0.281
0.311
+-0.030
0.75A (max) at 264 VAC input and full load.
30A(0-peak)@ 110Vac ,50A(0-peak) @ 220Vac
(measured when switched off for at least 10 mins.)
Tolerance
+12Vdc
+/-5 %
6500
0.313
0.329
+-0.030
Output Current
-
MIN
0.1A
48 Watt max.
1.5Kvac or 2.2KVdc for 1 minute.
< 0.25mA/100Vac , <3.5mA/230Vac
80% min. @115V/230VAC, maximum load.
19
user
x1
y1
+-0.030
Volt Tolerance
MAX
5A