That is why you should not use the You should always make use of the appliance shortly after a renovation. materials prescribed by Faber Only by The first time the appliance is using these materials can Faber switched on, Let the fire run on guarantee a proper functioning.
transit through combustible wall or Prepare the gas connection to the gas ceiling constructions. And observe control valve. sufficient distance. Make sure that the concentric flue Moving the appliance materials are bracketed every 2 If necessary the upper parts of the appliance metres when they have an extended can be taken of, this gives a minimum length, so that the weight of the flue...
Before proceeding with the installation of the Placing the decorative material fire Install the side and front glass of the fire to check the squareness (See chapter 6) It is not allowed to add different or more With a correct squareness of the unit, all materials to the combustion chamber.
Now slide the glass up into the upper If the inlet pressure is too high you groove and then place the glass in the are not permitted to connect the bottom groove appliance. 6.2 Placing the front glass Measuring the burner pressure: Only perform this measurement if the Note: first install the right side part inlet-pressure is correct.
Conversion to a different type of of 1.5 For the Respect count measured value gas (e.g. propane) Co2 in the fresh air, this will not have a bad This can only be done by installing the proper effect for the working of the appliance. burner unit.
11.5 90° bends in the horizontal direction Calculation of flue system Only bends in the horizontal direction. Indicated as I, K and Q. (fig.12.1,12.2 and Using the flue calculation spread sheet, you 12.3) can make a flue calculation. (see chapter.13) There is also a App.
Page 16
13 Flue calculation spread sheet Starter length (STL) First part on top of the appliance value Flue length from 0,1m till 0,45m Flue length from 0,5m till 0,90m Flue length from 1m till 1,4m Flue length from 1,5m till 2m Flue length from 2M or more Bends 90°...
Page 17
found value Search in the table at TVH and THL and enter the value that is found Is the detected value is a number check whether the completed STL is higher or equal to the value in the table. Is the found value x a is the situation is not possible, Solution: change the TVH or THL STL value is less than as specified in the Table installation is Not possible Solution: Start length to low see for the minimum length in the top row of the table...
Page 18
Technical data Gascat. II2H3+ II2H3+ II2H3+ Type C11 C31 C11 C31 C11 C31 Reference gas Input Nett 14.5 14.6 13.2 Efficiency class NOx class inlet-pressure mbar Gas rate at 15ºC and 1013 mbar 1533 Gas rate at 15ºC and 1013 mbar gr/h 1140 Burner pressure at full mark...
Need help?
Do you have a question about the Respect OC and is the answer not in the manual?