9. A/D DATA CHECK
This menu is used to display the A/D conversion
value of the microprocessor which detects panel keys
of this unit and protection functions by using the sub-
menu.
When K0/K1 menu is selected, keys become non-
operable due to detection of the values of all keys.
However, it is possible to advance to the next main
menu by turning the "PROGRAM" knob of this unit.
*
The figures in the diagram are given as reference
only.
PS1/PS2
PSx:
Power supply voltage protection detection
PS1
Voltage detects: AC_BL, AC_12, AC_5, ±12 and
+5V
Normal value:
38 to 128
(Reference voltage: 3.3 V=255)
PS2
Voltage detects: -5 and +5I
Normal value:
31 to 125
(Reference voltage: 3.3 V=255)
*
If PS1 or PS2 becomes out of the normal value
range, the protection function works to turn off
the power.
DC/TH
DC:
Power amplifier DC (DC voltage) output is
detected.
Normal value:
23 to 70
(Reference voltage: 3.3 V=255)
TH:
Temperature on the heatsink is detected.
Normal value:
0 to 124
(Reference voltage: 3.3 V=255)
*
If DC or TH becomes out of the normal value
range, the protection function works to turn
off the power.
9. A/D DATA CHECK
本機パネルキー、プロテクションなどを検出してい
るマイコンの A/D 変換値を、サブメニューで表示し
ます。
K0/K1 のメニューにすると、全キーの値を検出するた
めキー操作はできなくなりますが、 本機の PROGRAM
ツマミを回すことにより、次のメインメニューに進
めることができます。
※ 図中の数値は参考例です。
PS1/PS2
PSx:
電源電圧プロテクションの検出
PS1
検出電圧: AC_BL、AC_12、AC_5、±12、+5V
正常値:
PS2
検出電圧: -5V、+5I
正常値:
※ PS1 または PS2 が正常値を外れるとプロテク
ションが働き、電源が切れます。
P S 1 : 0 8 9
2 : 0 7 7
DC/TH
DC:
パワーアンプ DC(直流電圧)出力の検出
正常値:
TH:
ヒートシンク温度の検出
正常値:
※ DC または TH が正常値を外れるとプロテク
ションが働き、電源が切れます。
D C : 0 4 9 T H : 1 1 8
RX-V1065/HTR-6280/AX-V1065
38 ∼ 128
(基準電圧:3.3 V = 255)
31 ∼ 125
(基準電圧:3.3 V = 255)
23 ∼ 70
(基準電圧:3.3 V = 255)
0 ∼ 124
(基準電圧:3.3 V = 255)