Download Print this page

Service Procedures - Vermont Castings 1610 Service Manual

Defiant non-catalytic

Advertisement

SERVICE PROCEDURES

Defiant Non-Catalytic Model 1610 Woodstove
Wear gloves, a dust mask and protective eyewear when servicing a stove. **
**
Replacing the Fountain Assembly
1. Remove the doors, andirons and the bottom grate. Carefully slide the refractory shoe out of the unit being
careful not to damage the gasket on the bottom (FIG. 1).
2. Take out the right side brick and insulating panel by removing the Phillips head screw holding the bracket
(FIG. 2) and carefully sliding the items out.
FIG. 1 Remove shoe
3. Remove the flue collar by backing out the two Phillips round head machine screws.
4. Remove the top. The top is held in place by two hex head bolts in the rear left and right corners of the top
(FIG.3) and by one socket flat head screw in the outside center of the top near the griddle opening (FIG. 4).
FIG. 3 Remove bolts in the top rear corners - shown
left rear
FIG. 2 Remove side brick and insulation panel
FIG. 4 Remove flat head socket screw