Download Print this page

jablotron CA-1802 ATHOS Installation Manual page 5

Mode 2 for cars with an original remote control for central lockin
Hide thumbs Also See for CA-1802 ATHOS:

Advertisement

16
SIREN
17
SET
18
AUXA
19
AUXB
25
ON
26
OFF
Events:
30
Alarm
31
Alarm cancelled by a user
32
Fire alarm
33
Tamper alarm
34
Disarming
35
Arming
36
Low battery voltage
37
Engine is blocked
38
Engine is unblocked
Source:
40
Ignition key
41
Door contact
42
INP1 activation
43
INP2 activation
44
Low battery voltage sensor
45
Telephone 1
46
Telephone 2
47
Telephone 3
Use only ASCII character set during the text editing.
10
Internet remote access
The web site www.GSMLink.cz enables car alarm remote control (to
users) and setting (to installers).
To get internet access to an installed and powered car alarm you will
first be asked to register your car alarm on the first page. You will find a
unique registration code for your car alarm on the warranty card.
11
Central monitoring station communication
The GSM communicator allows central monitoring via GPRS data protocol.
The central monitoring station (CMS) gets arming, disarming and alarm
information. It also regularly checks the communication link to the car after it
is armed. So if anyone tries to tamper with GSM communications, it will
indicate an alarm at the CMS.
12
Additional features
12.1 Car battery low voltage reporting
The built-in voltage drop detector can trigger an alarm if an electrical
device in the car is turned on while the car is armed. The sensor is active
10 minutes after arming.
12.2 Passive guarding
Via the DIP I parameter it is possible to block the car against starting up the
engine, if the ignition key is turned off for 5 minutes and the alarm is not set.
The function can be turned off by arming or disarming. It is also possible to
set up the parameter to send a STATUS SMS, which informs the user that
the alarm is not set; in the case that the ignition key is turned off for 60
minutes and the alarm was not set.
12.3 Remote siren activation
You can operate the siren remotely by the SIREN instructions. These
instructions are accepted from all authorized (stored) phone numbers.
Commands are also accepted from any unknown phone number if they start
with the USER code.
Instruction
SIREN ON
SIREN OFF
SIREN
SIREN xxM
or
SIREN xxxS
12.4 Limited number of alarms
If any sensor (input) repeatedly triggers alarms then this particular input will
be bypassed automatically after the third alarm (it will remain bypassed until
the car alarm is disarmed).
12.5 LED indicator signals
LED state
OFF
permanently ON
Regular slow flashing
Regular fast flashing
GSM car alarm CA-1802 „Athos"
64
Car alarm reports
65
Status:
66
Armed
67
Disarmed
68
Ignition key ON
69
Ignition key OFF
70
Engine is blocked
71
Engine is unblocked
72
No alarm
73
Alarm timeout
74
Low battery voltage
75
Power failure
76
Power recovery
77
Time
79
Partially
Confirmation SMS:
81
Command accepted
82
Command syntax error
83
New MC code:
84
New UC code:
85
Reset
86
Registered phone number:
87
Credit:
88
LEARN mode, enrolled
Status
activates SIR output permanently
deactivate SIR output
activates SIR output for 30 sec.
xxM – is the numeric value of the
duration of SIR output activation, in
minutes
xxxS – as above, but in seconds.
Meaning
Disarmed
Connecting to a GSM network or a phone
call
Armed
Alarm memory
Interrupted light
Flashing after ignition off
Flashes after ignition on
12.6 Pre-paid SIM card balance
It is recommended not to use prepaid cards in the car alarm. If you have
no other choice than prepaid cards, you can enable the CREDIT
instruction by the following sequence:
MASTER CREDIT uuu..u xx yyy zz
where: uuu...u is the provider's code to obtain the balance
xx
is the time period (in days) for regular checking
yyy
is the threshold level below which the balance is
reported to the user (TEL1)
zz
is the position of the first digit of the balance in the reply
SMS from the provider
After this sequence has been sent once, the car alarm will check
the balance automatically every xx days and if the balance is lower
than yyy the user will be notified (TEL1)
If the CREDIT instruction is enabled in the above way, the user
can also obtain the current balance by the instruction CREDIT
To disable the automatic balance checking set the time period "xx"
to 00.
12.7 Roaming
If you travel abroad and your SIM card supports roaming, the car alarm
will work there too except for the LOCATOR and CREDIT functions and
GPRS data communication which will not be available.
12.8 Reset GSM
If you need to disconnect and then reconnect the GSM module to the
GSM network, then use the command "MASTER RESET GSM".
This does not affect any settings and is typically used for GPRS
activation or charging up credit. This command always requires the
MASTER code.
12.9 Service instruction
The DINFO instruction allows you to obtain current settings, information
about the quality of the GSM signal, the registration code for GSMLink
devices and some other parameters. This command always requires the
Master code.
Example of instruction: MASTER DINFO
Example of response: Car alarm reports: CA-1802A, SN:123456, SV:01,
LV:03, RK:ABCDE-12345-FG67, R:01, GSM:25, Time:3.2.06 11:35
CA-1802A
SN:123456
SV:01
LV:03
RK: ABCDE-12345-FG67
R:01
GSM:25
instant quality of GSM signal (ranging from 0 to 32 (best))
13
AUX output
AUX output can be set to one of the following modes.
External sensor power supply – if set to this mode, the output
switches to +12V when the car alarm is armed. Current limit is 20mA.
AUX bus – this mode allows you to connect up to four CR-11A modules
to the bus. This enables you to extend car alarm functionality via the
power output. There are two outputs available: A and B. They can be
operated by pressing two buttons together on the key fob RC-8x (see
instructions to CR-11A), or using SMS instructions. This allows you to
operate independent heating, refrigerators, flashing lights etc.). The car
must not be immobilized by use of this module, because the output
reacts to incoming SMS instructions in every state of the car alarm, in
particular, while the car is on the run, thus possibly not under the user's
control which could cause a traffic accident.
Instruction
AUXA (B)
AUXA ON (OFF)
AUXB ON (OFF)
AUXA xxM in xxxS
AUXB xxM in xxxS
Example of an instruction to switch B relay on for 30 seconds:
AUXB 30S
* Maximum switch-on time is 60 minutes.
* If a relay (A or B) is switched on while arming the car, it will be
switched off. In addition, the A relay, when switched on, will also be
switched off while disarming the car.
5/6
Car was stopped (immobilization)
GSM network is not available
Number of enrolled remote controls
car alarm version
identification number of the product
software version
language version
registration code for GSMLink
current Reset mode of the device
Status
Relay switches on for 1 second
ON - Switch on permanently*
OFF – Switch off permanently*
xxM – numeric value of requested
duration of the relay to be switched
on, in minutes
xxxS – as above, in seconds
MHF57308

Advertisement

loading