Installation manual: CA-1802 "Athos" – mode 3
Main features for this mode:
• Sending SMS messages automatically after the inputs have been
activated and sending information SMS messages to up to 4
mobile phones.
• Dialling pre-programmed phone numbers after input activation
and giving an acoustic warning signal.
• Passing data to the central monitoring station.
• Remote immobilization (blocking the circuit) via SMS instructions.
1
Before installation
The CA-1802 GSM pager should only be installed by a professional
installer. It is designed to be installed inside a car. A voltage supply of 12V
or 24V is required with a negative ground connection. During the first
power-up, the value of supply voltage is read and the inputs are set to
default settings.
Disconnect the car battery before starting installation. For airbag-
equipped cars, no person is allowed to stay inside the car while handling
the battery. Disconnecting the battery can cause a reset of some of the
car's devices (e.g. clock, default settings etc.). Avoid drilling into the metal
parts of the car body. The manufacturer is not responsible for damage
caused by any incorrect or unsuitable application of the product.
For crimping, special purpose tools should be used. If you do not use
some of the cables, cut them off at a distance of 10cm from the connector,
insulate them properly and tie them into a bunch.
For cars with a voltage supply of 24V, the following restrictions
apply to car alarm installation:
1.
It is not possible to connect a hands-free set of type HF-03.
2.
When used for acoustic signalling, the SIR output is switched
to the power supply voltage. Consequently, this output
switches to 24V, so it is necessary to use a siren of type SA-
606-24V (instead of the SA-530 which is supplied in the
standard package). This case also requires the siren
confirmation impulse to be extended to 100ms.
2
The wiring
Yellow – output siren – switches to +12V (24 V) / max. 1.3 A for 30
seconds after input activation (optional).
Grey – instant activation. It reacts to connection or disconnection
from ground (as an option, the detection of a passive state can be set
up). The reaction time is 70ms.
White – input INP. It reacts to a connection or a disconnection from
the ground (detection of a passive state is possible). The reaction time
is 3 seconds.
Blue – signals that the ignition key is turned on. Reacts to +12V
(24V). When you are installing it inside a car, make sure that a voltage
is present in the connecting wire while starting. The activation of input
INP is blocked during the ignition key input activation and, if installed, a
hands free set can be used.
Green – LED indicator – should be installed in a visible place on the
dashboard. The opposite end of the wire should be connected to
ground.
Black – ground – connect to the original grounding point.
Red – power supply +12V (24V) - connect directly to the battery. The
power should be turned on only after a thorough check of the whole
installation has been made!
Orange – back-up battery – connects to a back-up battery of type BB-
02 (capacity 450 mAh, consumption up to 20 mA.). This feature is
optional.
2x Brown – immobilization circuit (max. 8A constantly, 12A
intermittently).
Pink – output AUX – bus communication for modules CR-11A
It is possible to attach a hands-free set of type HF-03
able to phone via the GSM pager, and also to remotely listen-in after the
immobilization circuit has been blocked. The HF set connects to the RJ
connector on the front side of the car alarm unit.
1
these accessories are optional
GSM pager CA-1802 „Athos"
GSM pager for cars with an installed car alarm
2
. Using this you are
• Remote control and programming of the CA-1802 from a mobile phone.
• Hands-free calling and remotely listening-in to a space (receiving of
any incoming calls and dialling up to 4 pre-programmed phone
numbers).
• Extension of functions via the CR-11A module, for example, operating
an independent car appliance via SMS (12V only).
Internet access and configuration from the www.GSMLink.cz web site.
Suitable for cars with a dashboard voltage supply of 12V or 24V.
;
3
SIM card insertion
1. Make sure, that the PIN number on the SIM is disabled. If the SIM card
does not allow you to switch the PIN off, set the PIN to 0000. Remember
(note down) the phone number of your SIM card. It is recommended to
delete all original records in the SIM card's phone directory.
2. Insertion of the SIM card: using a thin object, press the yellow peg in
order to pull out the SIM card holder (the front side of the unit), insert the
SIM card into the casing with the conducting contacts facing up and push
the casing back carefully up to the sticking point.
3. Install and attach the GSM antenna– (the GSM pager must not be
connected to a power supply unless a GSM antenna is connected !!!). The
antenna is equipped with an adhesive tape and has to be stuck onto the car's
window. The antenna must not be installed to metal parts. The antenna should
not be installed close to the pager or near other electronic devices. It is
recommended to install the antenna in a place where it is not easily visible (like,
for instance, on a tinted part of the window). Clear and dry the spot carefully. If a
factory-installed GSM antenna is already present, you can connect it to the CA-
1802. Use an appropriate adapter if the connectors are different.
4. Check the wiring and connect the power supply. A flash of the indicator and
a beep of the siren (if connected) indicate connecting to the GSM network. Wait
until the indicator turns off (up to 1 minute). After that the CA-1802 is logged in to
the GSM network.
If the flash does not disappear within 1 minute, it means that the login
process failed. If such a case occurs, turn off the power supply, pull out the
SIM card, ensure that the SIM contacts are clean, insert the card into a
mobile phone and check, whether a connection can be established in that
particular place. Also make sure that the SIM card's PIN is turned off (or that
it is set to 0000). If the mobile phone connection check is successful, return
the SIM card to the GSM pager and repeat the whole procedure. At least 10
unused positions for phone numbers are required in the SIM card memory.
4
After turning the power supply on
In order to use the functionality of the GSM pager according to your needs you first
have to set up its logic and behaviour by the RESET command. Subsequently,
phone numbers and other optional parameters should be set up and an RC-8x key
fob can be enrolled. The set-up can be done in the following ways:
• by editing a record in the SIM card phone directory (it is the simplest
setting but limited to some functions only, see table 5.1). After the initial
powering up of the GSM pager with a SIM card, configuration records (names)
are created in the SIM card's phone directory which determine the devices'
behaviour. You can perform basic settings of some of GSM pager's functions
by pulling the SIM card out of the alarm (after the power supply has been
disconnected) and subsequently inserting it into a mobile phone where you
assign numbers to the names of functions displayed in the phone directory from
the SIM. See table 5.1 for setting the GSM pager's optional parameters.
Settings from the SIM card are read after its insertion and powering up.
• via the Internet page www.GSMLink.cz which is the most convenient
way. To register there you need the registration code printed on the
warranty card and the master code (factory default is MASTER). For more
information, see chapter 10.
• by sending command SMS messages via a mobile phone, see table
5.1.
Using the CA-1802 as a GSM pager, it is necessary to set RESET 3.
You can perform it by an SMS instruction "MASTER RESET 3" which has to
be sent to the GSM pager's SIM card number. Performing a RESET is
indicated by 4 beeps. The factory default is RESET 0 without any function
assigned, except that the immobilization relay switches on after the ignition
key has been turned on. It is possible to put the GSM pager to RESET 0
mode also in the case, that its functionality should be cancelled entirely.
By carrying out a RESET, you delete all the GSM pager settings as well as
all the previously enrolled remote controllers and wireless sensors.
1/5
MHF57400

Advertisement

loading

Summary of Contents for jablotron ca-1802 athos

  • Page 1 Installation manual: CA-1802 “Athos” – mode 3 GSM pager for cars with an installed car alarm • Remote control and programming of the CA-1802 from a mobile phone. Main features for this mode: • Sending SMS messages automatically after the inputs have been •...
  • Page 2 4. The RC-8x controller enrolled by pressing buttons Enrollment of remote controls simultaneously for approx. 3 seconds (at first, the LED has to flash quickly, then a single long flash should appear). A siren chirp confirms the enrollment. Up to 4 RC-8x remote controllers can be enrolled. This mode only allows By enrolling the first remote control all other remote controls previously enrolled the controllers to operate the HF-03 hands-free set.
  • Page 3 Configuration table - be careful to put spaces between words in SMSes (e.g. MASTER RESET 3). SIM entry* SMS instruction Text Description RESET 3 (After MASTER RESET 3 Mode setting. RESET 3 = GSM pager for cars with an installed car alarm. Performing the RESET which, the entry instruction is indicated by 4 beeps.
  • Page 4: Additional Features

    • If an SMS instruction is sent from an unauthorized phone, it is HELP Wireless detector 4 necessary to put a user code before the instruction (default is USER). CREDIT Wireless detector 5 Again, a space is necessary. Example: USER IMO DIAL Wireless detector 6 •...
  • Page 5: Specification

    The original of the conformity particular, while the car is on the run, thus possibly not under the user’s assessment can be found at www.jablotron.com, Technical Support section control which could cause a traffic accident. Note: Although this product does not contain any harmful materials we...