Daikin FNA35A2VEB Operation Manual
Daikin FNA35A2VEB Operation Manual

Daikin FNA35A2VEB Operation Manual

Split system air conditioners
Hide thumbs Also See for FNA35A2VEB:

Advertisement

Quick Links

Operation manual

Split system air conditioners
FNA25A2VEB
FNA35A2VEB
Operation manual
FNA50A2VEB
English
Split system air conditioners
FNA60A2VEB

Advertisement

Table of Contents
loading

Summary of Contents for Daikin FNA35A2VEB

  • Page 1: Operation Manual

    Operation manual Split system air conditioners FNA25A2VEB FNA35A2VEB Operation manual FNA50A2VEB English Split system air conditioners FNA60A2VEB...
  • Page 2: Table Of Contents

    2 About the system Latest revisions of the supplied documentation may be available on the regional Daikin website or via your installer. Components ................Information related to units using R32 refrigerant ..... The original documentation is written in English. All other languages are translations.
  • Page 3: Information Related To Units Using R32 Refrigerant

    3 Before operation CAUTION Do NOT turn off the breaker, unless you smell something burning, or during a short repair period, inspection, or cleaning of the unit. Otherwise, refrigerant leakage cannot be detected. CAUTION Do NOT install or use in highly airtight spaces, e.g. soundproof chambers or rooms with sealed doors.
  • Page 4: Operation

    4 Operation WARNING Outdoor units using R410A refrigerant Outdoor unit Cooling Heating Do not place a flammable spray bottle near the air conditioner and do not use sprays. Doing so may result in RQ71~125 Outdoor –5~46°C DB –9~21°C DB a fire. temperature –10~15°C WB WARNING Indoor...
  • Page 5: Energy Saving And Optimum Operation

    5 Energy saving and optimum operation WARNING Energy saving and optimum R410A is a non-combustible refrigerant, and R32 is a operation mildly flammable refrigerant; they normally don’t leak. If the refrigerant leaks in the room and comes in contact with fire CAUTION from a burner, a heater, or a cooker, this may result in a fire (in case of R32), or the formation of a harmful gas.
  • Page 6: Cleaning The Air Filter, Suction Grille, Air Outlet And Outside Panels

    7 Troubleshooting Cleaning the air filter, suction grille, air outlet and outside panels 6.2.1 To clean the drain pan Clean the drain pan so that it does NOT become clogged and dusty. Cover the drain pan to prevent dust from entering it. 4 Dry the air filter in the shadow.
  • Page 7: Symptoms That Are Not System Malfunctions

    7 Troubleshooting Malfunction Measure Malfunction Measure If the user interface display indicates the Notify your installer and The fan is rotates, Refrigerant leakage sensor started unit number, the operation lamp flashes report the error code. even when the unit is working: and an error code appears.
  • Page 8: Symptom: White Mist Comes Out Of A Unit (Indoor Unit)

    8 Disposal the user interface and the actual operation is different from the NOTICE user interface setting. For multi-split models, the microcomputer Do not try to dismantle the system yourself: the dismantling executes the following control depending on the operation mode of the system, treatment of the refrigerant, oil and other of other indoor units.
  • Page 12 4P456953-1 2017.06...

This manual is also suitable for:

Fna25a2vebFna60a2vebFna50a2veb