Specification - Viessmann VITODENS 200-W Installation And Service Instructions Manual

Type b2ha, b2ka, 3.2 to 35 kw gas council no. -system boilers: 41-819-32; 41-819-33; 41-819-34; 41-819-35 -combi boilers: 47-819-28; 47-819-29; 47-819-30
Table of Contents

Advertisement

Specification

Specification
Rated voltage
Rated frequency
Rated current
Safety category
IP rating
Permissible ambient temperature
■ During operation
■ During storage and
transport
System boiler (type B2HA)
Rated heating output range
at T
/T
50/30 °C
V
R
at T
/T
80/60 °C
V
R
for DHW heating
Rated heat input range
Power consumption
In the delivered con-
dition
Maximum
Connection values relative to the max. load
Natural gas E
LPG P
Product ID
Only when operating with LPG.
*2
180
230 V
50 Hz
6 A
I
IP X 4 D to
EN 60529
0 to +40 °C
–20 to +65 °C
kW
3.2 - 19
*2
(4.8 - 19)
kW
2.9 - 17.5
(4.3 -
*2
17.5)
kW
2.9 - 17.5
(4.3 -
*2
17.5)
kW
3.1 - 17.9
(4.5 -
*2
17.9)
W
53
W
65
3
1.89
m
/h
kg/h
1.40
Electronic tempera-
ture limiter setting
Temperature limiter
setting
Backup fuse (power
supply)
5.2 - 26
5.2 - 30
*2
(8.8 - 26)
(8.8 - 30)
4.7 - 24.1
4.7 - 27.8
(8.0 -
*2
24.1)
4.7 - 24.1
4.7 - 27.8
(8.0 -
*2
24.1)
4.9 - 24.7
4.9 - 28.5
(8.3 -
*2
24.7)
68
103
2.61
1.93
_-0085CN0050
82 °C
100 °C (fixed)
max. 16 A
5.2 - 35
*2
(8.8 - 35)
4.7 - 32.2
(8.0 -
(8.0 - 32.2)
*2
27.8)
4.7 - 32.2
(8.0 -
(8.0 - 32.2)
*2
27.8)
4.9 - 33.0
(8.3 -
(8.3 - 33.0)
*2
28.5)
76
106
119
3.02
3.49
2.23
2.58
*2
*2
*2
*2
89