Dinstar DAG1000-1S User Manual

Dinstar DAG1000-1S User Manual

Analog telephone adapter
Hide thumbs Also See for DAG1000-1S:
Table of Contents

Advertisement

DAG1000-1S/2S/4S Analog Telephone Adapter
User Manual V1.0
Dinstar Technologies Co., Ltd.
th
Address: 9
Floor, Guoxing Building, Changxing Road, Nanshan District, Shenzhen, China
Postal Code: 518052
Telephone: +86 755 61919966
Fax: +86 755 2645 6659
Emails: sales@dinstar.com, support@dinstar.com
Website:
www.dinstar.com
DAG1000-1S/2S/4S User Manual
I
Copyright©2011-2017 Dinstar

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the DAG1000-1S and is the answer not in the manual?

Questions and answers

Summary of Contents for Dinstar DAG1000-1S

  • Page 1 DAG1000-1S/2S/4S Analog Telephone Adapter User Manual V1.0 Dinstar Technologies Co., Ltd. Address: 9 Floor, Guoxing Building, Changxing Road, Nanshan District, Shenzhen, China Postal Code: 518052 Telephone: +86 755 61919966 Fax: +86 755 2645 6659 Emails: sales@dinstar.com, support@dinstar.com Website: www.dinstar.com DAG1000-1S/2S/4S User Manual...
  • Page 2: About This Manual

    2.19.10.01 Adapter User Manual V1.0 Conventions ATA or device mentioned in this document refers to the DAG1000-1S, DAG1000-2S or DAG1000-4S analog telephone adapter. Those words in red are the contents that users need to pay attention to. DAG1000-1S/2S/4S User Manual...
  • Page 3: Table Of Contents

    1 Product Introduction ........................1 1.1 Overview ..............................1 1.2 Application Scenario ...........................1 1.3 Product Appearance ............................2 1.3.1 Appearance of DAG1000-1S .......................2 1.3.2 Appearance of DAG1000-2S .......................3 1.3.3 Appearance of DAG1000-4S .......................3 1.4 Features & Functions ...........................4 1.4.1 Key Features ............................4 1.4.2 Physical Interfaces ..........................4...
  • Page 4 4.5 SIP Server ..............................29 4.6 Port ................................32 4.7 Advanced ..............................34 4.7.1 FXS Parameter ..........................34 4.7.2 Media Parameter ..........................36 4.7.3 SIP Parameter ............................ 37 4.7.4 Fax Parameter ............................ 44 4.7.5 Digit Map ............................45 DAG1000-1S/2S/4S User Manual Copyright©2011-2017 Dinstar...
  • Page 5 4.12.3 Data Restore ............................ 70 4.12.4 Ping Test ............................70 4.12.5 Tracert Test ............................71 4.12.6 Outward Test ........................... 71 4.12.7 Network Capture ..........................72 4.12.8 Factory Reset ........................... 74 4.12.9 Device Restart ..........................74 5 Glossary............................75 DAG1000-1S/2S/4S User Manual Copyright©2011-2017 Dinstar...
  • Page 6: Product Introduction

    SOHO and small enterprises. Moreover, with automatic provisioning and centralized management system, the device is easy for maintenance and deployment. 1.2 Application Scenario The application scenario of DAG1000-1S/2S/4S analog telephone adapter is shown as follows: Figure 1-1 Application Scenario of DAG1000-1S/2S/4S IP Phone...
  • Page 7: Product Appearance

    1 Product Introduction 1.3 Product Appearance 1.3.1 Appearance of DAG1000-1S Front View: Back View: Table 1-1 Description of Indicators and Interfaces of DAG1000-1S Indicator Definition Status Description The device is powered on. Power Indicator There is no power supply or power supply is abnormal.
  • Page 8: Appearance Of Dag1000-2S

    For the description of indicators and interfaces of DAG1000-2S, please refer to Table 1-1. 1.3.3 Appearance of DAG1000-4S Front View: Back View: For the description of indicators and interfaces of DAG1000-4S, please refer to Table 1-1. DAG1000-1S/2S/4S User Manual Copyright©2011-2017 Dinstar...
  • Page 9: Features & Functions

    Fully compatible with leading IMS/NGN and SIP-based IP telephony systems  1.4.2 Physical Interfaces Telephone Port  DAG1000-1S: 1 FXS port (RJ11) DAG1000-2S: 2 FXS ports (RJ11) DAG1000-4S: 4 FXS ports (RJ11) Ethernet Interfaces  DAG1000-1S/2S/4S: 1 WAN, 10/100Mbps (RJ45) 1 LAN, 10/100Mbps (RJ45) 1.4.3...
  • Page 10: Fxs

    NAT: STUN, Static/Dynamic NAT  1.4.6 Software Features Hunting Group   Web ACL  Telnet ACL Action URL  PPPoE/IPv4/IPv6  Digitmap  Bandwidth Optimization  Routing Rules based on Prefixes   Caller/Called Number Manipulation DAG1000-1S/2S/4S User Manual Copyright©2011-2017 Dinstar...
  • Page 11: Supplementary Services

     Configuration Backup/Restore  Firmware Upgrade via Web    Syslog  Ping, Tracert Test Network Capture  Outward Test (GR909 Standard)  NTP/Daylight Saving Time  IVR Local Maintenance  Cloud-based Management  DAG1000-1S/2S/4S User Manual Copyright©2011-2017 Dinstar...
  • Page 12: Quick Installation

    Connection); 2.3 Network Connection DAG1000-1S/2S/4S works in two network modes: route mode and bridge mode. When it is under the route mode, the IP address of WAN port must be at different network segment from that of the LAN port. But when it is under the bridge mode, the IP address of WAN port is the same with that of LAN port.
  • Page 13: Network Connection Diagram Under Bridge Mode

    Generally, when the device works under the bridge mode, the IP address of the device has been modified. In the following diagram, it is assumed that the IP address has been modified into 172.16.80.1. Figure 2-2 Network Connection Diagram under Bridge Mode 172.16.80.XXX Switch/Router 172.16.80.1 DC12V FXS0 FXS1 DAG1000-2S DAG1000-1S/2S/4S User Manual Copyright©2011-2017 Dinstar...
  • Page 14: Preparations For Login

    2 Quick Installation Note: The IP address of PC and that of WAN port of the DAG1000-1S/2S/4S device are at the same network segment. 2.4 Preparations for Login Firstly, connect the device to network according to the above network diagrams, and connect a telephone to the FXS port.
  • Page 15: Basic Operation

    3.4 Call Transfer 3.4.1 Blind Transfer Blind transfer is a call transfer in which the transferring party connects the call to a third party without notifying the third party. DAG1000-1S/2S/4S User Manual Copyright©2011-2017 Dinstar...
  • Page 16: Attended Transfer

    B presses the flash hook and dials 2 , the conversation will switch to B and C; if A presses the flash hook and dials 3, the conversation will switch to A , B and C (which is named DAG1000-1S/2S/4S User Manual Copyright©2011-2017 Dinstar...
  • Page 17: Description Of Feature Code

    3 Basic Operation ‘three-way calling’). 3.6 Description of Feature Code DAG1000-1S/2S/4S provides convenient telephone functions. Connect a telephone to the FXS port and dial a specific feature code, and you can query corresponding information. Code Corresponding Function *159# Dial *159# to query WAN IP...
  • Page 18: Send Or Receive Fax

    Under the T.38 mode, analog fax signal is converted into digital signal and fax signal tone is restored according to the signal of peer device. Under the T.38 mode, fax traffic is carried in T.38 packages. DAG1000-1S/2S/4S User Manual Copyright©2011-2017 Dinstar...
  • Page 19: Function Of Rst Button

    Adaptive Fax Mode: automatically match with the fax mode of the peer device. 3.8 Function of RST Button Press the RST button of DAG1000-1S/2S/4S for a moment, the running indicator will turn from “slow flashing” into “no flashing”, and then turn into “slow flashing” again. That means the device has been restored to factory defaults.
  • Page 20: Configurations On Web Interface

    4 Configurations on Web Interface Configurations on Web Interface 4.1 Navigation Tree The web management system of the DAG1000-1S/2S/4S VoIP device consists of the navigation tree and detailed configuration interfaces. Choose a node of the navigation tree to enter into a detailed configuration interface.
  • Page 21: System Information

    Network modes include bridge and router. Under the Bridge mode, the Network Mode device will work as a small LAN switch, and IP addresses of LAN port and WAN port are the same. Under the Route Mode, NAT feature will DAG1000-1S/2S/4S User Manual Copyright©2011-2017 Dinstar...
  • Page 22 Succeed: the DAG1000 device is sync to NTP server successfully; NTP Status Failed: the DAG1000 device fails to be sync to NTP server. Then you should check network connection and the NTP server. Total bytes of message received and sent by WAN port. Traffic DAG1000-1S/2S/4S User Manual Copyright©2011-2017 Dinstar...
  • Page 23: Registration

    Figure 4-3 Registration Status of Each FXS Port or Port Group SIP User status: Registered: the port or port group is registered to SIP server successfully; Unregistered: the port or port group fails to be registered to SIP server. DAG1000-1S/2S/4S User Manual Copyright©2011-2017 Dinstar...
  • Page 24: Tcp/Udp Statistics

    FXS ports of the DAG1000 device. You can also export, filter or clear the CDRs. 5000 pieces of CDRs can be saved at most. Figure 4-6 CDRs of FXS Ports DAG1000-1S/2S/4S User Manual Copyright©2011-2017 Dinstar...
  • Page 25: Record Statistics

    4.4.1 Local Network The DAG1000-1S/2S/4S device has two kinds of network mode: route and bridge. When the device works under the route mode, it will work as a small router and NAT function is enabled. Under this situation, WAN port is normally connected to router/switch or ADSL MODEM, while LAN port is connected local computer or other network device (such as Ethernet switches, Hubs etc.).
  • Page 26 IP Address: the IP address of the WAN port of the DAG1000;   Subnet Mask: the netmask of the router connected the DAG1000; Default Gateway: the IP address of the router connected the DAG1000;  DAG1000-1S/2S/4S User Manual Copyright©2011-2017 Dinstar...
  • Page 27  When the device works under the route mode, log in the device’s web configuration interface via the LAN port.  After the configurations are completed, please restart the device for the configurations to take effect. Figure 4-9 Network Setting under Bridge Mode DAG1000-1S/2S/4S User Manual Copyright©2011-2017 Dinstar...
  • Page 28: Vlan(Virtual Local Area Network

    Set the priority of a VLAN based on 802.1P protocol. 0 is the 802.1p Priority(0-7) highest priority. Network Setting Set a DHCP IP address or static IP address for a VLAN, and set the IP address of the DNS server used by the VLAN. DAG1000-1S/2S/4S User Manual Copyright©2011-2017 Dinstar...
  • Page 29: Dhcp Option

    The DAG1000 device can label QoS priority on the IP messages it sends out, so as to resolve network delay or network congestion. Meanwhile, the device can give different QoS tags for management-related packets of Web/Telnet, voice packets and signal packets. DAG1000-1S/2S/4S User Manual Copyright©2011-2017 Dinstar...
  • Page 30: Lan Qos

    IP address will no longer be used by network equipment. Subnet mask, default gateway, DNS server will be transmitted to network equipment through the DHCP protocol. Generally, they are the same with those of the DAG1000 device. DAG1000-1S/2S/4S User Manual Copyright©2011-2017 Dinstar...
  • Page 31: Dmz Host (Route Mode)

    【Note】: The IP address of the DMZ host needs to be at the same network segment with LAN port; after the configurations are finished, please restart the DAG1000 device for the configurations to take effect. DAG1000-1S/2S/4S User Manual Copyright©2011-2017 Dinstar...
  • Page 32: Forward Rule (Route Mode)

    DMZ Host. 4.4.9 Static Route (Route Mode) Static route determines the routing rule during the handling of messages by the DAG1000 device. Generally, you do not need to configure static route. Only when there are multiple DAG1000-1S/2S/4S User Manual Copyright©2011-2017 Dinstar...
  • Page 33: Firewall (Route Mode)

    4.4.10 Firewall (Route Mode) When the DAG1000 device works under the route mode, the firewall function can help filter some IP addresses, mac addresses and domain names. DAG1000-1S/2S/4S User Manual Copyright©2011-2017 Dinstar...
  • Page 34: Arp

    SIP server is the main component of VoIP network and is responsible for establishing all SIP calls. SIP server is also called SIP proxy server or register server. Both IPPBX and softswitch can act as the role of SIP server. DAG1000-1S/2S/4S User Manual Copyright©2011-2017 Dinstar...
  • Page 35 The IP address or domain name of the primary SIP server. It is provided by VoIP service provider. Address The service port of the primary SIP server. It is 5060 by default. Primary SIP Server port DAG1000-1S/2S/4S User Manual Copyright©2011-2017 Dinstar...
  • Page 36 Simple SIP server is only responsible for the establishment, maintenance and cleaning of sessions, while relatively-complex SIP server (SIP PBX) not only provides basic calling and conversational support, but also offers rich services such as Presence, Find-me and Music On Hold. DAG1000-1S/2S/4S User Manual Copyright©2011-2017 Dinstar...
  • Page 37: Port

    Parameters of the SIP account include port number, whether to register, primary display name, primary SIP user ID, primary Authenticate ID, primary Authenticate password, off-hook auto-dial number, caller ID and so on. Figure 4-21 Configure SIP Account for Port Registration DAG1000-1S/2S/4S User Manual Copyright©2011-2017 Dinstar...
  • Page 38 If call waiting is enabled, a special tone is sent if another caller Call Waiting tries to reach you If call waiting tone is enabled, caller will hear special tone. Play Call Waiting Tone DAG1000-1S/2S/4S User Manual Copyright©2011-2017 Dinstar...
  • Page 39: Advanced

    On the Advanced FXS/FXO page, you can configure FXS parameters which include timeout for dialing, timeout for answer, call progress tone, auto gain control, send polarity reversal, detect hook flash, CID type and so on. Figure 4-22 Configure FXS Parameters DAG1000-1S/2S/4S User Manual Copyright©2011-2017 Dinstar...
  • Page 40 The time how long the caller ID will be delayed when the caller ID after Ringing is set to be displayed after ringing. Default value is 500ms. Timeout for ‘call forwarding on no answer’ service CFNRy Timeout DAG1000-1S/2S/4S User Manual Copyright©2011-2017 Dinstar...
  • Page 41: Media Parameter

    If this parameter is enabled, the DAG1000 device will choose a Use Random Port port by random as the start port for RTP. When ‘Use Random Port’ is not selected, you need to configure RTP Start Port DAG1000-1S/2S/4S User Manual Copyright©2011-2017 Dinstar...
  • Page 42: Sip Parameter

    SIP Parameter SIP parameters include subscriber for MWI, voicemail user ID, IP-to-IP call, anonymous call, call confirm tone, call waiting response code, caller-ID preferred, attended transfer trigger, early media, session timer, heartbeat interval and so on. DAG1000-1S/2S/4S User Manual Copyright©2011-2017 Dinstar...
  • Page 43 The expiry time of MWI subscription; Default value is 3600s. Voicemail User ID The user ID used to access to voicemail There are two visual MWI Type, namely NEON and FSK Visual MWI Type Figure 4-25 Configure SIP Parameters DAG1000-1S/2S/4S User Manual Copyright©2011-2017 Dinstar...
  • Page 44 Send New REGISTER when be automatically updated and REGISTER will be re-sent after Recv 423 Response receiving of 423 response. If this parameter is enabled, the value of CSeq starts with CSeq Start with 1 ‘1’. DAG1000-1S/2S/4S User Manual Copyright©2011-2017 Dinstar...
  • Page 45 18x Response Preferred ‘Local Ring Tone Only’ Flashhook Operation Mode Choose Mode one, Mode two or Mode three Choose ‘Onhook’ or ‘Flashhook +4’ Attended Transfer Trigger Figure 4-26 Configure Default SIP Parameters & Early Media DAG1000-1S/2S/4S User Manual Copyright©2011-2017 Dinstar...
  • Page 46 The minimum interval for refreshing session; default value is 1800s. Min-SE The Min-SE header field indicates the minimum value for the session interval. Session Refresh Method The method to refresh session; default value is INVITE. DAG1000-1S/2S/4S User Manual Copyright©2011-2017 Dinstar...
  • Page 47 Here takes the DAG1000-2S device together with Elastix as the example to introduce how voicemail works in the device. (1) After the device registers to Elastix server, enable the voicemail function in Elastix for the corresponding extension number and then set password. As below: DAG1000-1S/2S/4S User Manual Copyright©2011-2017 Dinstar...
  • Page 48 (4) Set ringing time in Elastix. Elastix will prompt user to leave a message after the corresponding extension rings 15 seconds (by default). Then the Elastix sever will record the message. Related setting is shown as follows: DAG1000-1S/2S/4S User Manual Copyright©2011-2017 Dinstar...
  • Page 49: Fax Parameter

    ID and password for authentication. After that user will hear voice message. 4.7.4 Fax Parameter The DAG1000-1S/2S/4S device supports the three fax modes: T.38 (IP-based), T.30 (Pass-Through) and Adaptive Fax Mode (automatically match with the peer fax mode). Figure 4-28 Configure Fax Parameters Table 4-12 Explanation of Fax Parameters There are three fax modes: T.38, T.30(Pass-through), and...
  • Page 50: Digit Map

    Dialplan is used for number dialing of calls through FXS ports of the DAG1000 device. It supports DigitMap. Figure 4-29 DigitMap DigitMap Syntax: Digit Supported Timer Objects A digit, a timer, or one of the symbols of DTMF A, B, C, D, #, or * DAG1000-1S/2S/4S User Manual Copyright©2011-2017 Dinstar...
  • Page 51: System Parameter

    NAT. STUN works with many existing NATs, and does not require any special behavior from them. STUN doesn’t support TCP connection and H.323. NTP (Network Time Protocol)is a computer time synchronization protocol. DAG1000-1S/2S/4S User Manual Copyright©2011-2017 Dinstar...
  • Page 52 The IP address of primary NTP server; default IP address is address us.pool.ntp.org. Primary NTP server The service port of primary NTP server; default port is 123. port Secondary The IP address of secondary NTP server ; Default IP address is server address 64.236.96.53 DAG1000-1S/2S/4S User Manual Copyright©2011-2017 Dinstar...
  • Page 53: Call & Routing

    Parameters of port group include registration, primary display name, primary SIP user id, primary authentication ID and password, secondary display name, secondary SIP user id, secondary authentication ID and password, off-hook auto dial, auto dial delay time, port select, etc. DAG1000-1S/2S/4S User Manual Copyright©2011-2017 Dinstar...
  • Page 54 User ID of this SIP account, which is provided by VoIP service Primary/Secondary provider (ITSP). It is usually in the form of digit similar to phone SIP User ID number or an actual phone number. DAG1000-1S/2S/4S User Manual Copyright©2011-2017 Dinstar...
  • Page 55: Ip Trunk

    A peer-to-peer VoIP call occurs when two VoIP phones communicate directly over IP network without IP PBXs between them. IP trunk helps establish peer-to-peer call between gateway and VoIP phones. IP trunk will be used in routing configuration. DAG1000-1S/2S/4S User Manual Copyright©2011-2017 Dinstar...
  • Page 56: Routing Parameter

    Figure 4-33 Configure Routing Parameter Table 4-16 Explanation of Routing Parameters IP IP Routing Choose whether to enable IP  IP routing. If this parameter is enabled, calls from IP network will be routed to IP phones. DAG1000-1S/2S/4S User Manual Copyright©2011-2017 Dinstar...
  • Page 57: Ip  Tel Routing

    If the called number is Callee Prefix 008675526456659, the called prefix can be 0086755 or 00.,“any” means the prefix matches any called number Calls to Which port or port group to which calls are routed. DAG1000-1S/2S/4S User Manual Copyright©2011-2017 Dinstar...
  • Page 58: Tel  Ip/Tel Routing

    Callee Prefix 008675526456659, the called prefix can be 0086755 or 00. ‘any’ means the prefix matches any called number. Choose calls are routed to a port, port group, IP trunk or SIP server Calls to DAG1000-1S/2S/4S User Manual Copyright©2011-2017 Dinstar...
  • Page 59: Ip  Ip Routing

    Choose calls are routed to which IP trunk. 4.9 Manipulation Number manipulation refers to the change of a called number or a caller number during calling process when the called number or the caller number matches the preset rules. DAG1000-1S/2S/4S User Manual Copyright©2011-2017 Dinstar...
  • Page 60: Ip  Tel Callee

    Calls to Determine the call is routed to a port or a port group. Stripped Digits The number of digits which are lessened from the left of the called number from Left DAG1000-1S/2S/4S User Manual Copyright©2011-2017 Dinstar...
  • Page 61: Tel  Ip/Tel Caller

    Determine the calls come from a port or a port group. Set a prefix for caller number. The prefix’s length is less than or equal to Caller Prefix that of the caller number, which helps to match the caller number of this DAG1000-1S/2S/4S User Manual Copyright©2011-2017 Dinstar...
  • Page 62: Tel  Ip/Tel Callee

    The suffix added to the caller number after its digits are lessened. Suffix to Add 4.9.3 Tel  IP/Tel Callee On the Tel  IP/Tel Callee page, you can set rules for manipulating the called number of Tel  IP/Tel calls. DAG1000-1S/2S/4S User Manual Copyright©2011-2017 Dinstar...
  • Page 63 Calls to server. Stripped Digits The number of digits which are lessened from the left of the called number from Left The number of digits which are lessened from the right of the called Stripped Digits DAG1000-1S/2S/4S User Manual Copyright©2011-2017 Dinstar...
  • Page 64: Management

    TR069 Parameter Table 4-23 Explanation of TR069 Parameters Choose whether to enable TR069; it is ‘not enable’ by default. TR069 ACS URL The IP address or domain name of ACS, which is provided by service provider. DAG1000-1S/2S/4S User Manual Copyright©2011-2017 Dinstar...
  • Page 65: Snmp

    (and, in some circumstances, manipulated) by managing applications. Three significant versions of SNMP have been develop. SNMPv1 is the original version of the protocol. More recent versions, SNMPv2c and SNMPv3, feature improvements in performance, flexibility and security. DAG1000-1S/2S/4S User Manual Copyright©2011-2017 Dinstar...
  • Page 66 4 Configurations on Web Interface Figure 4-41 Configure SNMP Parameters Table 4-24 Explanation of SNMP Parameters SNMP The DAG1000 device supports three versions of SNMP, namelyV1、V2C and V3. DAG1000-1S/2S/4S User Manual Copyright©2011-2017 Dinstar...
  • Page 67 User configuration exists in V3. When V3 transmits SNMP packets in an Configuration encryption way, this item needs to be configured. User: fill in a user name used to authenticate. AuthType: choose MD5 or SHA as authentication type. DAG1000-1S/2S/4S User Manual Copyright©2011-2017 Dinstar...
  • Page 68: Syslog

    Provision Provision is used to make the DAG1000 device automatically upgrade with the latest firmware stored on an http server, an ftp server or a tftp server. Please refer to the Instruction for Using Provision. DAG1000-1S/2S/4S User Manual Copyright©2011-2017 Dinstar...
  • Page 69: Cloud Server

    Password Password for logging in provisioning server 4.10.5 Cloud server You can register the DAG1000 device to cloud server, and then the device can be managed by the cloud server. Figure 4-44 Configure Cloud Server DAG1000-1S/2S/4S User Manual Copyright©2011-2017 Dinstar...
  • Page 70: User Manage

    In case that you need remote technical support, technical support engineers can connect your device with a service server on the Management Remote Server page, so as to better help you to solve problems. Figure 4-46 Configure Remote Server DAG1000-1S/2S/4S User Manual Copyright©2011-2017 Dinstar...
  • Page 71: Action Url

    ACL (Access Control List) for Web is used to configure IP addresses that are allowed to access the Web Interface of the DAG1000 device. The IP address list can’t be null once ACL is enabled. DAG1000-1S/2S/4S User Manual Copyright©2011-2017 Dinstar...
  • Page 72: Telnet Acl

    Telnet interface of the DAG1000 device on this page. Note: Both the username and password of Web and Telnet are ‘admin’ and ‘admin’ by default. It is advised to modify them for security consideration. DAG1000-1S/2S/4S User Manual Copyright©2011-2017 Dinstar...
  • Page 73: Encrypt

    Note: If SIP encrption is enabled, heartbeat and anonymous calls should be disabled. 4.12 Tools 4.12.1 Firmware Upload On the Tools  Firmware Upload page, you can upload a new firmware version from a local folder. DAG1000-1S/2S/4S User Manual Copyright©2011-2017 Dinstar...
  • Page 74: Data Backup

    Step 5. Reboot the device on the Tools  Device Restart page. 4.12.2 Data Backup On the Tools  Data Backup page, you can download and backup configuration data, device status and summary messages on local computer. Figure 4-53 Backup Data DAG1000-1S/2S/4S User Manual Copyright©2011-2017 Dinstar...
  • Page 75: Data Restore

    1. Enter the IP address or domain name of a network, a website or a device in the input box of Ping, and then click Start. 2. If related messages are received, it means the network works normally; otherwise, the network is not connected or is connected faultily. Figure 4-55 Execute Ping Test DAG1000-1S/2S/4S User Manual Copyright©2011-2017 Dinstar...
  • Page 76: Tracert Test

    Figure 4-57 Execute Outward Test Test Results: OK: the physical function of the tested FXS ports is working well; FAIL: There’s something wrong with the physical function of the tested FXS ports. DAG1000-1S/2S/4S User Manual Copyright©2011-2017 Dinstar...
  • Page 77: Network Capture

    Syslog capture is another way to obtain syslog which is the same as remote syslog server and filelog. The captured file is save as pcap format so that it can be opened in some of capturing software like Wireshark, Ethereal software etc. Figure 4-59 Capture Syslog Packages DAG1000-1S/2S/4S User Manual Copyright©2011-2017 Dinstar...
  • Page 78  Save the capture to local computer The captured package is named ‘capture(x).pcap’, amont which x is the serial number of the capturing and will be added 1 in next time. The sample of RTP capture as below: DAG1000-1S/2S/4S User Manual Copyright©2011-2017 Dinstar...
  • Page 79: Factory Reset

    Figure 4-62 Reset Device to Factory Default Setting 4.12.9 Device Restart For some configurations or changes to the DAG1000 device, you are required to restart the device for the configurations or changes to take effect. Figure 4-63 Restart Device DAG1000-1S/2S/4S User Manual Copyright©2011-2017 Dinstar...
  • Page 80: Glossary

    Public Switched Telephone Network Pulse Code Modulation Quality of Service VLAN Virtual Local Area Network Session Initiation Protocol STUN Simple Traversal of UDP over NAT SNMP Simple Network Management Protocol Real Time Protocol User Datagram Protocol DAG1000-1S/2S/4S User Manual Copyright©2011-2017 Dinstar...

This manual is also suitable for:

Dag1000-2sDag1000-4s

Table of Contents