Convergence - Sony TRINITRON KV-PG21P10 Service Manual

Bg-2t chassis
Hide thumbs Also See for TRINITRON KV-PG21P10:
Table of Contents

Advertisement

KV-PG21P10
RM-952

3-2. CONVERGENCE

Preparation :
Before starting this adjustment, adjust the focus, horizontal
size and vertical size.
Receive dot/hatch signal.
Pic mode: Soft.
(1) Horizontal and Vertical Static Convergence
Center dot
R
G
B
H. STAT VR
1. (Moving vertically), adjust the V.STAT magnet so that the
red, green and blue dots are on top of each other at the
center of the screen.
2. (Moving horizontally), adjust the H.STAT VR control so
that the red, green and blue dots are on top of each other at
the center of the screen.
3. If the H.STAT variable resistor cannot bring the red, green
and blue dots together at the center of the screen, adjust the
horizontal convergence with the H.STAT variable resistor
and the V.STAT magnet in the manner given below.
(In this case, the H.STAT variable resistor and the V.STAT
magnet influence each other, so be sure to perform adjust-
ments while tracking.)
Purity
DY pocket
V.STAT
R
G
B
V. STAT
Magnet
RV702
H. STAT
CV Board
BMC
BMC (Hexapole)
Purity
V.STAT
Operation of V. Stat magnet
If the V. Stat magnet is moved in the "a" and "b" arrows, the
red, green and blue dots move as shown below.
1
a
b
2
a
a
R
G
B
3
b
4
BMC (Hexapole) Magnet.
If the red, green and blue dots are not balanced or aligned,
then use the BMC magnet to adjust in the manner described
below.
R G
B
R
B
G
– 14 –
a
B
b
G
G
R
b
b
B
G
R
a
a
B
R
G
b
B
R
G
B
R
G B
R
G
B
G
R
B
b
B
R
b
G
R

Hide quick links: