Features; Flue Manifolds - Rinnai ES38 Owner's Operation And Installation Manual

Energysaver gas direct vent wall furnace
Table of Contents

Advertisement

Appliance Specifications
Natural Gas
Propane Gas
Minimum supply gas pressure
5.0 in (127 mm) W.C.
11.0 in (280 mm) W.C.
Maximum supply gas pressure
10.5 in (267 mm) W.C.
13.0 in (330 mm) W.C.
BTU/hour input
Low 10,500
High 38,400
Low 10,500
High 36,500
BTU/hour output
Low 8,400
High 30,720
Low8,400
High 29,200
Features
• Restarts automatically when ignition or combustion
• Clean the Air Filter - Indicator Lamp
fails.
• Clean Heating Forced Flue Type
• Easy Operation One-Touch Ignition
• Sensible Temperature Control Feature
• Comfortable Room Temperature Control and
Display
• Energy Saving Economy Setting
• Humidifier Tray
• Air Flow Directional Louvers
• Direct Vent Easily Installed
• Proportional Heating Variable Capacity
• Warm Air Outlet at Floor Level (keeps your feet
warm)
• Hush! Quiet Operation
• Modern Design Minimizes Floor Space
Requirements
• Function Lock
• Room Temperature Setting Memory
Flue Manifolds
The following flue manifold sizes are
available for different wall thicknesses:
• Fault Code Message Display
Name
Kit No.
fits walls
S Vent Kit
FOT-150
3 - 4 1/2 in (75 - 115 mm)
A Vent Kit
FOT-151
4 1/2 - 9 1/2 in (115 - 240 mm)
B Vent Kit
FOT-152
9 1/2 - 15 3/4 in (240 - 400mm)
C Vent Kit
FOT-153
15 3/4 - 23 5/8 in (400 - 600 mm)
D Vent Kit
FOT-154
23 5/8 - 31 1/2 in (600 - 800 mm)
Rinnai Corporation ES38 Manual