Test 5: Calling For Heat - No Blower Operation - A.O. Smith SERIES 120 Service Handbook

Commercial gas water heaters
Hide thumbs Also See for SERIES 120:
Table of Contents

Advertisement

TEST 5: CALLING FOR HEAT - NO BLOWER OPERATION

Conditions:
Power on
Plugs in Receptacles
Red " Call for Heat" LED - ON
Blower (Draft Inducer) off
Note flash code on ignition control board diagnostic LED.
TEST 5
IF.........
Pin 1 to ground check has no voltage
Pin 1 to ground has voltage
Pin 3 to ground has no voltage
Servicing should only be performed by a Qualifi ed Service Agent
TROUBLESHOOTING
Water Heater Control - Thermostat
"Call for Heat"
LED Indicator
Diagnostic LED
Indicator
120
Figure 24
then............
• reset control by interrupting power. Note possible reasons for this from flashing LED code.
• replace ignition board.
Proceed
• check wiring harness and plugs.
• replace blower.
Ignition Control Board
Ground
31

Advertisement

Table of Contents
loading

This manual is also suitable for:

Btr 500/aSeries 121

Table of Contents