Installation - Comfort Glow QWH2100 Operator's Manual

Wall mount quartz infrared electric heater
Table of Contents

Advertisement

Available languages

Available languages

INSTALLATION

WARNING:
If the heater is being installed in a residential garage, it must be secured firmly to the wall, a minimum of 36 inches
(457mm) above the floor. The heater must be located so that it is protected against any possibility of damage by a
moving vehicle, etc.
Raising the heater will reduce BUT NOT eliminate the possibility of lighting the vapor of any flammable liquids which
may be improperly stored or accidentally spilled. If the smell of gasoline is present, do not operate this heater until the
area has been properly ventilated.
MINIMUM CLEARANCES TO COMBUSTABLES
LEFT/RIGHT
TOP
*12 Inches
36 Inches
Top clearance is from top of the heater to ceiling or other
combustible material
Bottom clearance is from the bottom of heater to surface of carpet,
tile or other combustible material.
* A sidewall must be at least 18 Inches away from the side of heater.
-Always maintain a 36 Inch clearance from any furniture, draperies or
other combustible material.
~ 5 ~
BOTTOM
FRONT
36 Inches
36 Inches
REAR
0 Inches