8-4. SAFETY DEVICE

OUTDOOR UNIT
FUSE
(SIDE OF POWER SUPPLY TERMINAL)
FUSE ON MAIN PCB
FAN MOTOR PROTECTION
COMPRESSOR PROTECTION
FUSE (SIDE OF POWER SUPPLY TERMINAL)
FUSE (SIDE OF INDOOR UNIT)
FUSE ON MAIN PCB
FAN MOTOR PROTECTOR
HIGH PRESSURE PROTECTION
DISCHARGE THERMISTOR
COMPRESSOR THERMISTOR
FUSE
(SIDE OF INDOOR UNIT TERMINAL)
FUSE ON MAIN PCB
FAN MOTOR PROTECTOR
HIGH PRESSURE PROTECTION
DISCHARGE THERMISTOR
COMPRESSOR THERMISTOR
PROTECTION FORM
-
-
-
THERMAL PROTECTOR
PRESSURE SWITCH
THERMAL SWITCH
PROTECTION FORM
-
-
-
-
THERMAL PROTECTOR
PRESSURE SWITCH
THERMAL PROTECTOR
THERMAL PROTECTOR
PROTECTION FORM
-
-
-
THERMAL PROTECTOR
PRESSURE SWITCH
THERMAL PROTECTOR
THERMAL PROTECTOR
08-09
AO*24LMAKL
25A 250V
3.15A 250V
5A 250V
150±5°C OFF
4.2MPa
OFF 120±5°C
ON 85±7°C
AO*30LMAWL
AO*36LMAWL
25A 250V
25A 250V
10A 250V
10A 250V
3.15A 250V
3.15A 250V
5A 250V
150±5°C OFF
150±5°C OFF
OFF:4.2±0.1MPa
OFF:4.2±0.1MPa
ON:3.2±0.15MPa
ON:3.2±0.15MPa
OFF:120±5°C
OFF:120±5°C
ON:80±5°C
ON:80±5°C
OFF:130±5°C
OFF:130±5°C
ON:80±5°C
ON:80±5°C
AO*45LJBYL
AO*54LJBYL
10A 250V
10A 250V
3.15A 250V
3.15A 250V
5A 250V
150±5°C OFF
150±5°C OFF
OFF:4.2±0.1MPa
OFF:4.2±0.1MPa
ON:3.2±0.15MPa
ON:3.2±0.15MPa
OFF:120±5°C
OFF:120±5°C
ON:80±5°C
ON:80±5°C
OFF:130±5°C
OFF:130±5°C
ON:80±5°C
ON:80±5°C
5A 250V
5A 250V