SAFETY PRECAUTIONS
Read this entire section of operating
instructions before operating the machine.
WARNING
ELECTRIC SHOCK can kill.
 Do not touch electrically live
parts or electrode with skin or
wet clothing.
 Insulate yourself from work and
ground.
 Always wear dry insulating gloves.
FUMES AND GASES can be
dangerous.
 Keep your head out of fumes.
 Use ventilation or exhaust to
remove fumes from breathing
zone.
WELDING SPARKS can cause fire
or explosion.
 Keep flammable material away.
 Do not weld on closed
containers.
ARC RAYS can burn eyes and
skin.
 Wear eye, ear and body
protection.
PLEASE SEE ADDITIONAL WARNING
INFORMATION AT THE FRONT OF THIS
OPERATOR'S MANUAL.
DUTY CYCLE
The duty cycle of a welding machine is the percentage of
time in a 10 minute cycle at which the welder can operate
the machine at rated welding current.
60% duty cycle:
Weld for 6 minutes
Excessive extension of the duty cycle will maybe cause
the thermal protection circuit to activate.
THERMAL PROTECTION
®
The INVERTEC
machine is equipped with a thermal
protection device. When the machine has gone into
thermal overload, the output will be turned off and the
thermal indicator light will be turned "ON". When the
machine has cooled to a safe temperature, the Thermal
OPERATION
Break for 4 minutes
®
INVERTEC
CC400-S/-S PLUS
Indicator Light will go out and the machine may resume
normal operation.
Note:
The machine's welding output will be available after a
thermal protection shutdown.

GENERAL DESCRIPTION

The INVERTEC CC400-S/-S PLUS is a 400A arc welding
power source that utilizes three phases input power, to
produce constant current output. The welding response of
this INVERTEC has been optimized for stick (SMAW) and
TIG (GTAW).
OPERATIONAL FEATURES AND
CONTROLS
FRONT PANEL (SEE FIGURE B.1)
FIGURE B.1
1. A/V DISPLAY SWITCH
When the switch is in position "A" the meter will indicate
preset current or actual output current; When the switch
is in position "V" the meter will indicate actual output
voltage.
2. CURRENT CONTROL POT
This controls the output current. This control may be
adjusted while under load to change power source
output. When using remote control this function becomes
disabled.
3. LOCAL/REMOTE SWITCH