Cleaning under the unit, where dust tends to accumulate, is considerably easier. Easy maintenance Filter is equipped as standard accessory; and it can be removed and cleaned easily due to Midea’s sophisticated design as well as the removable blades. Streamlined appearance makes it much more harmonious with the decoration. All metal parts are made of commercial grade galvanized steel, providing maximum protection against corrosion.
DM16-01.01.02-09en MIV V4+ Indoor Units 2. Specifications MVF22A-VA1 MVF28A-VA1 MVF36A-VA1 Model MVB22A-VA1 MVB28A-VA1 MVB36A-VA1 Power supply V- Ph-Hz 220-240V, 1Ph, 50Hz Capacity Cooling Input Rated current 0.18 0.19 0.22 Capacity Heating Input Rated current 0.18 0.19 0.22 Model YSK20-4A YSK20-4A...
Page 5
MIV V4+ Indoor Units DM16-01.01.02-09en MVF45A-VA1 MVF56A-VA1 Model MVB45A-VA1 MVB56A-VA1 Power supply V- Ph-Hz 220-240V, 1Ph, 50Hz Capacity Cooling Input Rated current 0.22 0.43 Capacity Heating Input Rated current 0.22 0.43 Model YSK20-6 YSK28-4E Type AC motor Indoor Brand Yongan Welling fan motor Input...
Page 6
DM16-01.01.02-09en MIV V4+ Indoor Units MVF71A-VA1 MVF80A-VA1 Model MVB71A-VA1 MVB80A-VA1 Power supply V- Ph-Hz 220-240V, 1Ph, 50Hz Capacity Cooling Input 0.63 0.63 Rated current Capacity Heating Input 0.63 0.63 Rated current YSK74-4E YSK74-4E Model AC motor Type Indoor fan Yongan Yongan Brand 138.5...
MIV V4+ Indoor Units DM16-01.01.02-09en 3. Dimensions 3.1 Exposed Floor-standing (air inlet from front) Mounting hole, 4 4¡ Á ¦ µ 4¡ Á ¦ µ Gas side connector Air inlet grille Liquid side connector 149.5 149.5 Right Left Air outlet grille Cover Cover Unit: mm...
Page 8
DM16-01.01.02-09en MIV V4+ Indoor Units 3.2 Exposed Floor-standing (air inlet from bottom) Mounting hole, 4 4¡ Á ¦ µ 4¡ Á ¦ µ Gas side connector Liquid side connector Air inlet grille 149.5 149.5 Right Left Air outlet grille Cover Cover Unit: mm MODEL...
MIV V4+ Indoor Units DM16-01.01.02-09en 4. Service Spaces F4 series Vertical unit with casing , with air intake from front and air outlet on top, for installation on a wall or on feet on the floor. F5 series Vertical unit with casing , with air intake from below and air outlet on top, for installation on a wall or on feet on the floor.
DM16-01.01.02-09en MIV V4+ Indoor Units 5. Piping Diagrams motor flare nut gas side heat exchanger flare nut liquid side Floor Standing Type MVF-A-VA1 MVB-A-VA1...
1, during actual operation, these values are normally somewhat higher as a result of ambient conditions. 2, Semi-anechoic chamber conversion value, measured at a point 1m in front of the unit at a height of 1.5m. 9.2 Test value Sound test value dB(A) Model MVF22A-VA1 MVB22A-VA1 MVF28A-VA1 MVB28A-VA1 MVF36A-VA1...
DM16-01.01.02-09en MIV V4+ Indoor Units 9.3 Octave Band Level MVF36A-VA1 MVB36A-VA1 MVF22A-VA1 MVB22A-VA1 MVF45A-VA1 MVB45A-VA1 MVF28A-VA1 MVB28A-VA1 A udibility lim its of A udibility lim its of continuous w hite continuous w hite sound sound O ctave band center frequency ( H z )...