Section 5 Troubleshooting - JVC KD-X120EE Service Manual

Digital media receiver
Table of Contents

Advertisement

4.8
DC Offset error description
4.8.1 DC Offset detection circuit design
• Purpose:
To prevent breakdown, when occur DC offset between speak-
er output "+" and "-".
• Target:
Detect DC offset, then stop the Power Amp operation and shift
to specified condition.
4.8.2 Possible causes of DC offset at speaker output lines
(1) Mis-connection for Speaker output for example touch to car
body or battery line.
(2) Current leak of coupling capacitor for Power IC input.
(3) Current leak of AC-GND capacitor for Power IC AC-GND.
(4) Capacitor shorted of above parts due to foreign object.
E-Vol
C-in
C-in
C-tc
Win_TC
Win_In
R3
DC Error
4.8.3 Type of checking
4.8.3.1
To detect DC Offset Error
• Mis-connection
- Short any one speaker out line to GND or Vcc
• Capacitor leak
- Parallel 330kΩ to either any one of coupling cap or AC-GND
capacitor (to simulate current leakage of capacitor)
- Shorted either any one of coupling capacitor or AC-GND ca-
pacitor.
4.8.4 Detection Timing chart
2.0sec or more
1.5sec or more
0.8sec
PWIC_STBY
PWIC_MUTE
AUD_MUTE
Missconnect
detection period
Audio Pwr Amp
In 1
C-in
In 2
In 3
C-in
In 4
C-ac1
C-ac2
AcGnd
Sw5V
R2
Offset Detect
R1
Out
C3
Micon
R4
ADC In
0.7sec or more
1.0sec
Capacitor leak
Other (miss detection etc.)
detection period
detection period
(No.MA606<Rev.002>)19/20
4.8.5 Manipulate after detect DC Offset
• If detected error 10 consecutive times, and 10th error occurred
in "Mis-connect detection period", judge as "Mis-connect".
• If detected error 10 consecutive times, and 10th error occurred
in "Capacitor leak detection period", judge as "Capacitor leak ".
• If detected error 10 consecutive times, and 10th error occurred
in "Other detection period" and detected another 10 errors con-
secutively, then judge as "Other".
• If judge as "Mis-connect".
- turn off speaker output.
- display "MISWIRING", check wiring connection then reset.
- key access disable except button of Eject, Reset and service
mode
- record error in EEPROM "DC1 ERR"
- the product is able to be recovered by Reset button.
• If judge as "Capacitor leak ".
- turn off speaker output.
- display "WIRING", check wiring connection then reset.
- key access disable except button of Eject, Reset and service
mode
- record error in EEPROM "DC2 #" (# means counter number)
- the product can be recovered by pressing the Reset button
before the capacitor leak error counter reach "DC2 4".
After that, only clear the counter back to "0" can recover the
product.
• If judge as "Other" (manipulation same as mis-connect)
TROUBLESHOOTING
5.1
How to cancel DC offset error
Check to be sure the terminals of the speaker leads are covered
with insulating tape properly, then reset the product.
If an error message does not disappear even after a reset, there
is a need for internal repair.
5.2
How to clear DC offset error recorded in EEPROM
Refer to "4.5 DC Error Information Mode".
50ms
or more
SECTION 5

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents