Page 3
It is recommended, for the staff intended for sales and installation of NDC-B052 access control panel to take instruction courses conducted by the company.
The panel can control up to 64 access points. All access points are attached to NDC-B052 via expansion modules using RS485 bus. Up to 32 modules can be connected to the control panel.
Page 8
Specifications • Environmental requirements: • Operation temperature 0 °С … +55 °С; • Relative Humidity 80% relative at +35°С; • Physical dimensions: • Width 300mm • Height 310mm • Depth 80mm • Weight 2,45 kG • Nonerasable memory: • Identificators up to 20 000 •...
ID to another person after passing to the premises. If this function is on, NDC-B052 tracks an ID position – Inside or Outside the premises. On any attempt to pass in the same direction twice NDC- B052 denies access and stores “Access Denied, Antipassback”...
Page 10
To access the high security premises the presence of more than one person may be required . NDC-B052 allows assigning of up to 15 groups of people with access rights. The access is granted only in case when one person from each group is present.
Wiring Configurations Controls and connections on board Terminals assignment i t c i r c i t p i t c i t c t s r y l l e t t e t t t a t r t n t n i i t c l a r...
Control panels are supplied unloaded without expansion modules. It is necessary that you should connect expansion modules, readers and other devices to NDC-B052 to organize security and access control system. Besides, you should download the panel using Golden Gate software.
Control Panel Operation - Door is opened too long (door time expired) - Attempt of code matching (if the function is switched on during programming). Alarm output is activated, but the mode does not switch on in case of panel box tampering attempt.
Mounting Mounting NDC-B052 is supplied in a metal frame with the built-in battery backup. The access control panel is to be mounted in place easy to servicing . To mount the panel on the wall proceeds as follows: - open the front cover,...
RS485 bus receiver-transmitter. NDC-B052 access control panel can be connected to PC straight via null-modem cable or modem using this output. Ethernet Port The NDC-B052 access control panel is provided with UTP jack for Ethernet connec- tion. UDP protocol is supported. http://www.itvsystems.com.ua...
COM ports. In the bottom part of program window the result of search will be displayed. Data exchange between PC and NDC-B052 during search will be seen on blinking of LED4. If the controller (controllers) are not found out by the program, repeat search.
Page 19
Setting id and IP Address Choose necessary configuration changes and load them to the controller. To do this select 'Actions' > 'Configure device' menu items and press button In the bottom part of program window result of loading will be displayed. If testing of device passed successfully, and loading is not executed - the message "Con- figuration is not loaded, controller is in operation mode"...
Page 20
Setting id and IP Address press button, transfer obtained .reg file to the PC with installed 'Golden Gate' program and execute merge to system registry. Integrated Technical Vision Ltd http://www.itvsystems.com.ua...
After resettling to factory defaults panel's id is set to 0 value. Power Supply Wiring PSU 1,5 power supply unit with battery backup, manufactured by ITV Ltd, use is recommended. This power supply NDC-B052 unit provides +12V power rated at 1,5A.
Limited Warranty Limited Warranty Integrated Technical Vision Ltd warrants that for a period of eighteen months from the date of purchase, the product shall be free of defect in materials and workman- ship under normal use and that in fulfillment of any breach of such warranty, Integrated Technical Vision Ltd shall, at its option, repair or replace the defective equipment upon return of the equipment to its repair depot.
Need help?
Do you have a question about the NDC-B052 and is the answer not in the manual?
Questions and answers