ABB A155-M57 Operation Manual page 63

Hide thumbs Also See for A155-M57:
Table of Contents

Advertisement

Operation Manual / 4 Product description / A150-M.. - A155-M..
4
Monitoring operation
4.3.3
Speed differences with several turbochargers per engine
The speeds of all turbochargers on an engine vary only slightly from each other in standard
operation.
The difference between the highest and the lowest turbocharger speed must not be more than
3 %, relative to the speed limit n
If this permissible range of difference is exceeded, the following steps must be carried out:
Reduce the engine performance immediately to the point at which the maximum turbo-
charger speed does not exceed 70 % of n
If the engine cannot be stopped, it can continue to be driven at this reduced engine load or
turbocharger speed.
If a turbocharger surges continuously, the engine performance must be reduced further.
Measure the temperatures in the air lines and gas piping from and to the turbochargers
and compare with normal values. If clear deviations of temperature are found, the nearest
ABB Turbocharging Service Station has to be contacted.
Check the pressure loss of the alternative air inlet and compare it with normal values.
If the engine can be stopped temporarily:
Inspect air lines, gas piping and the turbochargers and remedy any malfunctions.
In any case, contacting the nearest ABB Turbocharging Service Station is recommended.
4.3.4
Malfunctions on the speed measurement system
In the case of malfunctions of the speed measurement system, refer to the chapter entitled
Troubleshooting/Speed measurement system [➙ 65].
© Copyright 2017 ABB. All rights reserved.
.
Bmax
.
Bmax
HZTL4032_EN
Page 31 / 120
Revision F
January 2017

Advertisement

Table of Contents
loading

Table of Contents